Comment: add and delete pass.
38. Weld Number xxx Pass
Maintenance Error
Last pass cannot be deleted.
39. Weld Number xxx Pass
Maintenance Error
No more passes to add
40. File Exists, unable to copy
Comment: copy weld program
41. File Copy Failed, le exists?
Comment: copy weld program
42. Delete Failed, le open?
Comment: delete weld program.
43. Load Failure Load failed; no such weld xxx
Comment: when loading next weld program if the next weld program is set wrong.
44. Load Failure File format error
Comment: wrong format weld program; old weld program
45. Load failure Go to library, review and resave weld.
Comment: because of old weld program.
46. Load Failure Error, time out to get response ###e-4
Comment: ### is a weld program number
47. Load Failure Failure to send weld. Check cables(# xxxe-3).
Comment: xxx is a weld program number
48. Load Failure S controller not alive, error xxxe-5
Comment: xxx is a weld program number; controller is not completely run as slave1
in update state.
49. Pendant Conguration Fail Data save failure EPC02; go back to Main menu and
try again.
Comment: code could be EPC03.
50. Pendant Conguration Done Remote control conguration has changed; reboot
the machine.