11. Autotack Failure Wall thickness and OD must be greater than zero.
12. Autotack Failure Wall thickness must be less than pipe radius.
13. New Weld Creation Amperage must be less or equal to 200.
Comment: creating or editing C, 150xx weld head welding program
14. New Weld Creation Amperage must be less or equal to xxx.
Comment: xxx is 200 for 300-series is the selected current.
15. New Weld Creation Travel Spd must be less than xxx IPM.
Comment: XXX is the maximum speed allowed for the selected weld head.
16. New Weld Creation Travel Spd must be less than xxx RPM.
Comment: XXX is the maximum speed allowed for the selected weld head.
17. New Weld Creation Wire Spd must be less than xxx IPM( ### mm/m).
Comment: XXX or ### is the maximum speed allowed for the selected weld head.
18. New Weld Creation AGC must be less than 15.
Comment: If in AVC mode, message is ”AVC must be less than 20”.
19. New Weld Creation AGC must be greater than 1.
Comment: If in AVC mode, message is ”AVC must be greater than 4”.
20. Error To pulse downslope, last pass must have pulsing on.
21. New Weld Creation Travel speed must be less than xxx IPM (### mm/m)
Comment: creating or editing general weld program for 300-series weld head
22. New Weld Creation OSC Amp must be greater than 1.01 mm.
23. New Weld Creation OSC Amp must be less than 17.08 mm.
24. New Weld Creation OSC Speed must be less than xxx IPS (### mm/m).