Operation Manual

49
A7 TIG Orbital System 300© Kemppi Oy 2016 1615
OPERATING MANUAL
5.4 Warnings/error messages
Certain internal and external problems will result in error messages and in some cases
further actions. For example:
If you attempt to start a weld without the ow of shielding gas, pressing the
start weld switch will result in an error message. The weld start sequence will
be terminated.
If gas ow is interrupted during the weld sequence, welding will be terminated
and the indicated error message will say: Weld Aborted: Check Gas Supply.
Message during welding
1. Welding Aborted Check gas supply
2. Welding Aborted Check water cooler, hoses and connections.
3. Arc Strike failure Reload when ready.
4. Arc failure Reload when ready.
5. OSC Out of Limits Comments shown in level screen during welding.
6. OSC Maybe Jammed Comments shown in level screen during welding.
7. OSC Out of Limits and Jammed Comments shown in level screen during welding.
8. Master Slave Comm Error Check master slave board
9. Slave Reset Error Check slave board
Communication Error between Pendant and Controller
Communications failure Press Main to try again or call Kemppi for help
Message during creating, editing, copying, deleting and setup
1. Autoprogram Failure Improper head selected; select 300-series weld head.
2. Autoprogram Failure Wall thickness and OD must be greater than zero.
3. Autoprogram Failure Wall thickness must be less than pipe radius.
4. Autoprogram Failure OD and/or wall thickness is out of range for the
selected weld head.
5. Program Failure This weld head is not supported by current software.
6. New Weld Creation Guide ring factor must be greater than zero with the
selected weld head.
7. New Weld Creation Guide ring factor must be less than 1638 with the
selected weld head.
8. New Weld Creation OD should be less than 163 inch with the selected
weld head.
9. New Weld Creation OD should be less than 4140 mm with the selected
weld head.
10. Autotack Failure Improper weld head selected; must be R or C head.