Operation Manual
37
A7 TIG Orbital System 300© Kemppi Oy 2016 1615
OPERATING MANUAL
3.6 Prepurge – Upslope
Move the cursor and enter values with the control knob.
Press Next when nished.
• Prepurge: Time period gas ows at weld start
before arc ignition (seconds).
• Upslope: Time period in seconds that weld
current ramps up from start amps value to level 1
value.
• Travel Delay: Period (seconds) beginning at
end of upslope before rotation begins. Used to
establish penetration.
• Start Amps: Current level at which arc is initiated.
• Start Delay: Arc gap control (AGC) operation start
delay (in seconds after arc initiated).
• Wire Start Delay: Wire feed operation start delay
(in seconds after arc initiated).
• Pulsing: Upslope, choice of pulsed current (Yes) or
stated current during upslope period (No).
Downslope At Home: If this function is OFF, program
downslope occurs at the time out (completion) of the
nal level. If this function is turned ON with the control
knob, program downslope will begin exactly as the Home
position switch is actuated. Because there are 4 possible
Home positions, welding always starts at one of them.
After a full 360° revolution, downslope will occur at 360°
Home.
3.7 Programmed oscillation width
(without striking an arc)
• Test Mode: If a program has already been written,
running the program in Test Mode will cause the
oscillator to move the torch at the programmed
width as it cycles through the program.
• Run Ready Mode:
a) For an existing program, cycle the program to a
level in which oscillation is being used and has a
programmed value.
b) Press the oscillation width "+" key one time.
This will cause the oscillator to weave at the
programmed value.
c) To terminate oscillation, press the "+" key a second
time, which will center the torch.
If you attempt to do the above in a level where there
is no oscillation being used (i.e. the root pass), nothing
happens when you hit the "+" key. However, the system will
be attempting to oscillate with a 0 value. If you attempt to
do anything else at this point, it will appear as if the system
has "locked up". Press the "+" key a second time to exit/
terminate this oscillation width observation mode.
• All other modes of operation: The oscillation
width "+" key cannot be used in most other
modes of operation (for example, when writing
a program) as it will increase the programmed
value.
a) To test the oscillation width in these modes, press
once the AGC Inhibit key in the left-hand bottom
corner of the remote control. This will oscillate the
torch for any level in which oscillation is being
used.
b) Press the AGC Inhibit key a second time to turn o
the oscillator and re-center the torch.