Operation Manual

27
A7 TIG Orbital System 300© Kemppi Oy 2016 1615
OPERATING MANUAL
3.3.3 Options Menu
Any changes made on this screen become active
immediately but are lost when the power is switched o. To
maintain changes, press Save after all changes are made on
the screen.
Setting the weld counter
At completion of each weld, the system stores the actual
parameters run and related weld ID number, operator
name, and time and date to print out if necessary. The
weld number sequentially increases by one digit per weld.
You can set/reset the weld counter at any specic number
using the control knob.
Setting the password
Press Enter. Password screen appears. Press Enter. An
alphanumeric pop‐up eld appears. Enter a password up
to 10 characters using the technique described in section
Alphanumeric labeling. To conrm password, press Save.
Entering operators name
Enter operators name using the technique described in
section Alphanumeric labeling.
Setting date and time
Press Enter to select the Date/Time eld and set date and
time.
Setting the language
Use the control knob to scroll through the alternatives.
Setting the units of measure
The control knob lets you scroll between Standard and
Metric.
Using the test mode
If you need to use the test mode, use the control knob to
select Yes.
This mode allows simulation of an actual weld with
sequencing through the weld program and simultaneous
rotation of the weld head. By using this function You can
observe the rotation of the tungsten electrode while
changing the various levels of the program on the display.
It is a useful diagnostic tool if you suspect malfunction
during the weld mode. A service technician can operate
the system in a simulated weld mode without the need to
worry about the arc. In the test mode, the contactor signal
to the power supply is disabled, preventing initiation of
high frequency and a welding arc.
1. Exit the Options menu.
2. Select a program to run. TEST MODE appears on
the screen.
3. Press Start Weld.
Following the pre‐purge and current upslope time
interval, the rotation motor on the weld head becomes
operational. It will continue operation until current
downslope is over. If the Auto Rewind function has been
programmed to occur, it follows after the completion of
the simulated weld. The gas solenoid is pulled in during
pre‐purge, welding, and post‐purge.
For weld head models equipped with a ller wire
feeder, the ller wire feed motor is disabled during the test
mode.