3.3.2 Maintenance Menu
The Maintenance menu contains functions for general
maintenance tasks.
Copy Welds
Delete Welds
Print Welds
Tungsten Calc
Options
Weld Head / Supply Options
Calibrate head
Guide Ring Factor Lookup
In the Main Menu screen, press Menu. This will open the
Maintenance Menu screen. Most functions are password-
protected if this option is selected.
Copy Welds (power source internal memory)
You may want copy an existing weld program as a starting
point for creating a new weld program for a dierent tube
size using the editing feature.
1. In the Maintenance Menu screen, select Copy
Welds and press Enter.
2. Enter the program numbers for source weld and
destination weld, then press Copy.
The Copy function allows you to copy a weld program
within the power source’s internal memory. (For example,
an existing weld number 2 could be copied to weld
number 10, assuming no program number 10 exists.)
The program will not be deleted from weld number 2; two
copies of the program now exist.
When performing a Copy or Transfer to a destination
program of the same number, the new le does not write
over the existing le. You may delete the existing le or
select an unused destination program number.
Weld numbers 1–99 are les stored in the internal memory
of the power source.
Delete welds
The Delete function is used to remove unwanted programs
from memory.
1. In the Maintenance Menu, select Delete Welds and
press Enter.
2. Use the control knob to select a weld program.
3. Press Delete.
You can also use this feature to delete welds from a memory
stick if it has been installed and initialized. Program on the
stick is numbered 100 and higher.
Only existing weld programs are displayed in the
Delete screen.