Operation Manual
23
A7 TIG Orbital System 300© Kemppi Oy 2016 1615
OPERATING MANUAL
3.3 Controller unit menus
3.3.1 Main Menu
When the controller unit is rst turned on, the main display
remains o except for backlighting. After approximately
12 seconds the model, S/N, software release date, and last
calibration date appear on the display.
The main menu options of A7 TIG Orbital System are
Library, Help, Menu, and New.
• Library: access to library of existing procedures
• Help: detailed explanation of highlighted item
• Menu: access to various functions and system
conguration
• New: create a new weld program.
3.3.1.1 Library
The Library view includes a list of all welds currently saved
in the system. Press Enter to select one to work with.
Programs are listed. Use the up/down cursor to scroll
through the programs. Select program by using the Select
soft key. The following choices are displayed:
• Weld Number
• Run
• Review Parameters
• Review Notes
• Edit Weld
• Scale Weld
• Copy Welds
• Delete Welds
• Print Welds
Scroll through the list again. Make your selection.
To run a weld
1. Move cursor to Run (now highlighted in red). Press
Select (soft key).
• Screen shows the status of the weld head
position, AGC inhibit, and wire inhibit.
• Screen allows purging of backing gas and
coolant.
2. Press Start Weld to initiate weld or press Purge to
purge gas lines when rst connecting a weld head
to power source.