Operation Manual

23
A7 TIG Orbital System 300© Kemppi Oy 2016 1615
OPERATING MANUAL
3.3 Controller unit menus
3.3.1 Main Menu
When the controller unit is rst turned on, the main display
remains o except for backlighting. After approximately
12 seconds the model, S/N, software release date, and last
calibration date appear on the display.
The main menu options of A7 TIG Orbital System are
Library, Help, Menu, and New.
Library: access to library of existing procedures
Help: detailed explanation of highlighted item
Menu: access to various functions and system
conguration
New: create a new weld program.
3.3.1.1 Library
The Library view includes a list of all welds currently saved
in the system. Press Enter to select one to work with.
Programs are listed. Use the up/down cursor to scroll
through the programs. Select program by using the Select
soft key. The following choices are displayed:
Weld Number
Run
Review Parameters
Review Notes
Edit Weld
Scale Weld
Copy Welds
Delete Welds
Print Welds
Scroll through the list again. Make your selection.
To run a weld
1. Move cursor to Run (now highlighted in red). Press
Select (soft key).
Screen shows the status of the weld head
position, AGC inhibit, and wire inhibit.
Screen allows purging of backing gas and
coolant.
2. Press Start Weld to initiate weld or press Purge to
purge gas lines when rst connecting a weld head
to power source.