2.6 Wire spool
1
2
b
a
Swing the wire spool mounting bracket away from the
pipe to accommodate easy spool installation.
1. Install the wire spool on the mounting bracket.
a. Be sure to align anti-rotation pin in the sleeve
with the slot in the nylon nut.
b. Tighten the knurled knob to prevent accidental
unwinding.
2. Swing the mounting bracket back to its original
position.
3
3. Push the wire through the guide tube and insert
into groove on the lower feed roll.
4. Jog motor forward so that the wire passes the feed
roll.
5
6
7
7
5. Guide the wire into the liner and jog the motor
until wire end comes through nozzle.
6. Release about 10 cm and cut at the nozzle.
7. Adjust the position of the nozzle with knurled
adjustment screws.
If the wire slips within the wire feed mechanism, adjust
it for more positive feeding:
1. Loosen the two retaining screws on the roller arm.
2. Using an adjustable wrench or pliers, gently rotate
the tensioning arm to increase the spring force on
the drive roller.
3. Tighten both screws. This adjustment should not
be made with wire in the mechanism