Operation Manual

24
A7 TIG Orbital System 150© Kemppi Oy 2016 1615
OPERATING MANUAL
1. Input all information as in Autogen but select the
number of Passes and Levels.
2. Move the cursor to the desired line and use the
control knob or Enter and control knob for OD and
Wall Thickness.
3. You can turn on Auto tack program if necessary
using the control knob.
4. Press Next.
3.8.8 Pulsing levels
You can select pulsed or non-pulsed current. Move the
cursor and use the control knob to change selections.
Pulsing varies the current between high and low values.
3.8.9 RPM Step
RPM Step can be turned on/o. This function indexes
tungsten electrode rotation with pulsed current. Tungsten
electrode will rotate during low current pulse and stop on
high current pulse (or be set to run at a percentage of low
current speed). Press Next.