3.8.4 Override Limit function
You may override any of the pre-programmed values,
but only within the limits dened during programming.
The percentage of override limits can be individually
programmed for each parameter between 0–100% of the
programmed value.
You can gain sucient override capacity to compensate
for tube t variations, for example, but avoid to modify
the original program outside of specied heat input
limitations. The override limits are saved with each weld,
which allows dierent override values based on which the
weld is run.
Use cursor to select line, the control knob to modify.
3.8.5 Program information
1. Use cursor to select item, the control knob to
modify.
Certain items have been previously selected and
cannot be changed (i.e. Weld No., Data, OD, etc.). The cursor
will bypass these items. To add description under Project
and Drawing, see Alphanumeric Labeling.
2. Recording notes
Use cursor to select line for additional notes. Save if all
program selections have been completed (or press Back
to make corrections).
Use cursor to select line, the control knob to modify.
3. Next Weld to Run
You have two choices:
a. Repeat the weld program. At the
completion of a weld, the same program
will automatically be loaded, eliminating
the need to enter the weld number again.
b. Run a dierent weld program. Press Next
when nished.
Completion of programming
Press Main to exit to Main Menu. Press Run to immediately