Operation Manual

20
A7 TIG Orbital System 150© Kemppi Oy 2016 1615
OPERATING MANUAL
3.8.3 Using Auto program
You can automatically select certain default values by
using Autoprogram. For example, to always use four
levels. To change these default values, you must edit the
weld program after it has been generated.
1. Select Yes with the control knob. Press Next.
2. If Password Protection has been applied, you will
be asked for your password to continue.
3. Select Weld Number using the control knob.
4. Press Next when nished.
5. Use Back to move to previous screen.
1. Use the cursor to select each line (highlighted in
red).
2. Use the control knob to select Head Model and
Material.
3. Use Enter and the control knob to select and
change each digit of O.D. and Wall Thickness.
4. Press Next when nished.
Use cursor to select line and the control knob to modify
Next Weld to Run. You have two choices:
1. Repeat the weld program. At the completion of a
weld, the same program is automatically loaded so
that you don’t need to re-enter the weld number.
2. Run a dierent weld program to create work cycles.
Press Next when nished.