11.4 Attaching the A7 MIG G gun neck
This section describes how to attach the A7 MIG G gun
neck.
Figure 7: Attaching the A7 MIG G gun neck
3
1
4
2
5
1. A7 MIG 500-g gun neck
2. Hexagon wrench
3. Lock ring
4. Robot mount
5. 2 set screws
Proceed as follows:
1. Equip the A7 MIG 500-g gun neck (1) with a tip
adapter, contact tip, and gas nozzle.
2. Insert the A7 MIG 500-g gun neck (1), via the guide
grooves, into the robot mount (4) as far as it will go.
3. Tighten the set screws (5) with a hexagon wrench
(2). Tightening torque M = 2.5 Nm.
4. Close the lock ring (3) by rotating it to the left.
11.5 Attaching the A7 MIG W gun neck
This section describes how to attach the A7 MIG W gun
neck.
Figure 8: Attaching the A7 MIG W gun neck
3
1
4
5
2
1. A7 MIG gun neck 500-w
2. Positioning pin
3. Robot mount
4. Connection module
5. Retaining nut
Proceed as follows:
1. Equip the A7 MIG gun neck 500-w (1) with a tip
adapter, contact tip, and gas nozzle.
2. Introduce the positioning pin (2) into the marked
bore. The gun neck (1) can only be fastened in this
position.
3. Tighten the gun neck (1) with the retaining nut (5)
on the robot mount (3).
4. The gun neck (1) is now attached.
After the gun has been in use for several days, it may no
longer be possible to disconnect it by hand. To disconnect
it, use a suitable wrench. Do not use pliers to disconnect the
gun.