Operation Manual

15
Robot Gun Mount T2, T4© Kemppi Oy 2017 1712
OPERATING MANUAL
16. TROUBLESHOOTING
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing, unmounting, and repair work, the
following instructions must be adhered to:
Switch o the power supply.
Cut o the compressed air supply.
Pull the power plug.
In the event of any doubts or problems, please contact your retailer or the manufacturer.
Please also consult the operating instructions for the other welding components,
such as the power supply and air pressure line.
Problem Cause Solution
Robot gun mount cannot
be attached
Wrong gun mount used Use the correct gun mount
Robot Gun Mount T2 mounting ange is defective Send the robot mount for repair
Robot Gun Mount T2 does
not activate the stop signal
Cable not connected between the robot mount and the
cable assembly
Connect the cable
Cable defective Replace the cable
Robot gun mount switch defective Send the robot mount for repair
Robot Gun Mount T2
does not reset to the zero
position
Mounted load is too heavy Reduce the mounted load
Mechanical defect Observe the data provided by the manufacturer
Attachment parts (bracket etc.) not correctly connected Send the robot mount for repair
Check whether the attachment parts are properly connected
Robot Gun Mount T2
triggered when there is no
fault
Mounted load is too heavy
Robot speed is too high
Adapt the load to the specications
See Chapter 6