Operation Manual
13
Robot Gun Mount T2, T4© Kemppi Oy 2017 1712
OPERATING MANUAL
12.3 Connecting the helix cable
This section describes how to adjust the TCP.
The parts of the system are depicted in the gure below.
Figure 8: Connecting the helix cable
1
3
5
2
4
6
Proceed as follows:
1. Plug the helix cable (4) into the connector housing (6), using the angled male
connector (5).
2. Plug the ange plug (2) into the torch (3) and the cable assembly (1).
3. Lock both connectors to prevent their accidental disconnection.
4. For the switching function, see the functional diagram (10).
1. Cable assembly
2. Flange plug
3. Gun
4. Helix cable
5. Angled male connector
6. Robot Gun Mount T2
connector housing
13. OPERATION
The device may only be operated by qualied personnel.
Because the robot mount is integrated into the gun’s welding process, the operation
steps are performed after the relevant gun has been installed.
Please observe the operating instructions for the A7 MIG Gun 500-g or the A7 MIG Gun
500-w welding guns, as applicable.
14. UNMOUNTING
Unmounting may only be carried out by specialist personnel. Please make sure that
the shutdown procedures for all components mounted in the welding system are strictly
observed before removal from operation begins.
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing, unmounting, and repair work, the
following instructions must be adhered to:
• Switch o the power supply.
• Cut o the compressed air supply.
• Pull the power plug.
Removal from operation depends on the type of welding gun. Please observe the
operating instructions for the A7 MIG Gun 500-g or the A7 MIG Gun 500-w welding guns,
as applicable.