12. ROBOT GUN MOUNT T2
INSTALLATION
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing,
unmounting, and repair work, the following instructions
must be adhered to:
Switch o the power supply.
Cut o the compressed air supply.
Pull the power plug.
Read the safety instructions in this manual and the
separate safety instructions.
The system may only be installed by authorized personnel.
12.1 Fastening robot mount T2 to the robot
This section describes how to fasten robot mount T2 to the robot.
Before attaching Kemppi robot mount T2 (5), rst place the robot (7) in maintenance
position.
For fastening the gun (1) to the robot mount (5), a gun mount (2) is required.
The parts of the system are depicted in the gure below.
Figure 6: Fastening robot mount T2 to the robot
3
6
1
4
7
2
5
891011121314
1. Gun neck
2. Gun segment holder upper part
3. Dowel screw, 8 H7
4. Helix cable
5. Robot mount T2
6. Robot ange
7. Robot
8. Cylinder-head screw
9. Cylinder-head screws, M4×55 (6 pcs.)
10. Feather key
11. Gun segment holder lower part
12. Clamping ring
13. Cylinder head screw, M8
14. M8 nut with washer