Operation Manual

30
A7 MIG Welder© Kemppi Oy 2018 1804
INTEGRATION GUIDE
5.1.8 Watchdog settings
Watchdog
If your robot supports the watchdog functionality, select
the watchdog ON. Otherwise, set this feature OFF.
Timeout
Specify a timeout for the watchdog timer by using the
slider. The minimum timeout value is 0.1 s and maximum
is 5.0 s. This timeout value species how fast the welding
system stops welding if the robot stops sending eldbus
data. The robot must perform continuous transitions on
the Watchdog signal of the digital robot interface within
the timeout period.
5.1.9 Welding system time
Set the welding system time and date by picking up the
date from the pop-up calendar and typing the time to the
particular eld. If you want to synchronize the welding
system time with the time of the browser, press the NOW
button.
After conguring the welding system settings, click on the
Save button, in the bottom bar, to save all changes.