Operation Manual

29
A7 MIG Welder© Kemppi Oy 2018 1824
OPERATING MANUAL
4.3 Web user interface
To access the web user interface, make sure that the
network settings of the web user interface server are
correct and the network cable has been plugged in. The
cable connection and the network conguration are
described in the A7 MIG Welder Integration guide.
Open the web user interface with a web browser to by
typing a proper IP address to the browser’s address eld.
The IP address can be veried from the setup panel, Robot
Menu > Network settings > IP address.
The web user interface is used only for conguring
robotic welding settings. If manual welding is used with the
A7 MIG Welder, the conguration of the hand welding wire
feeder is done using the setup panel.
1
2
4 5
6
3
Figure 4.2 Web user interface layout overview
1. Side menu bar
2. Content frame
3. Current user / User logout
4. Setup parameters
5. Setup value controls
6. Pop-up bar (normally hidden)
Side menu bar
The side bar will be hidden if the width of the window is
narrowed down. A side bar button appears in the top left
corner of the window and can be used to show and hide
the side bar.
The menu items are shown according to the access
level of the current user. See Section 4.4 "User identication"
for more information.
Current user / User logout
Clicking the current username opens a drop-down list
with logout text. Clicking the text logs out the current
user and redirects automatically to the login window.
Setup parameters and controls
Many of the menu items contain user congurable
parameters. The setup parameters and their related
controls are listed from top to bottom. They are ordered
in functional groups to make system conguration easier.
Setup value controls
The controls allow you to change parameter values.
Dierent types of parameter values have controls of
types according to the parameter value range. The
controls can be button bars, edit boxes, drop-down lists,
sliders, and sliders with adjustable min and max limits.
The slider value can be provided as a direct value input
by clicking the current value and typing a new value.
Pop-up bar
The multi-function pop-up bar on the bottom of the
window is normally hidden and appears when needed.
The bar appears for error and warning notications and
for save changes requests. It allows the user to take
actions related to the notication and disappears after
one of the buttons has been clicked.