4.2.6 System tests
Test menu (Main menu 7/8)
Menu item Value range Factory value Description
1/4 Wire inch Run the wire inch test by
pressing the START soft
button and keeping it
pressed. The ller wire
is driven forward by
accelerating to the selected
speed. The test stops when
the button is released.
Speed 0.5 - 25.0 m/min 5.0 m/min Select the wire feed speed in
0.05 m/min steps from 0.5 to
5.0 m/min and in 0.1 m/min
steps above 5.0 m/min.
WF motor Displays the motor current
during the test.
2/4 Wire retract Run the wire retract test
by pressing the START
soft button and keeping
it pressed. The ller wire
is driven backwards by
accelerating to the selected
speed. The test is stopped
when the button is released.
Speed 0.5 - 25.0 m/min 5.0 m/min Set the wire feed speed in
0.05 m/min steps from 0.5 to
5.0 m/min and in 0.1 m/min
steps above 5.0 m/min.
WF motor Displays the motor current
during the test.
3/4 Gas test Run the gas test by pressing
the START soft button once.
The test is run until the test
time goes o or until the
STOP soft button is pressed
(appears in the place of the
START button).
Test time 1 - 60 s 20 s Set how long the gas test is
run for.
4/4 Air blow Run the compressed air blow
test by pressing the START
soft button once. The test is
run until the test time goes
o or until the STOP soft
button is pressed (appears
in the place of the START
button).
Test time 1 - 60 s 20 s Set how long the air blow test
is run for.