Operation Manual

22
A7 MIG Welder© Kemppi Oy 2018 1824
OPERATING MANUAL
4.2.4 User settings
User settings menu (Main menu 2/8) (login required)*
Menu item Value range Factory value Description
1/5 Change PIN
code
Change your PIN code.
New PIN code 0000 - 9999 0000 Specify a new PIN code.
2/5 User mode ON, OFF OFF Set the user identication mode
on and o.
3/5 Set the user
rights
Change the role for a user.
Select user USER1 - USER10 Select the user whose role you
want to change. Note! You cannot
change your own role.
Level Welder,
Supervisor,
Administrator
Select the role for the user.
4/5 User activation Create and delete users.
User activation USER1 - USER10 Select the user account that you
want to create /delete.
User Enabled,
Disabled
Create an account by setting
the user Enabled, or delete the
account by selecting Disabled.
5/5 Reset user PIN
code
Reset the PIN code of a user.
Select user USER1 - USER10 Select the user whose PIN code
to reset. The reset value is 0000.
Conrm the reset by pressing OK
soft button.
* See section 4.4 User identication for more information.
4.2.5 Welding system settings
System cong menu (Main menu 4/8)
Menu item Value range Factory
value
Description
1/22 Water cooling OFF, ON, AUTO AUTO Set the water cooler on and
o, or let the system control
the cooler (AUTO). In auto
mode the water pump starts
when welding starts and
stops after a delay when
welding stops.
2/22 Cable length 10 - 100 m 10 m Set the welding circuit length
for optimal arc control.
3/22 FineCalib 0 V - 10 V /
100 A
10 V / 100 A Set the compensation for
cable resistance variation.
4/22 System clock View and modify the system
time and date.
5/22 Device information Review the following device
information for each device
in the system:
DevSW: Unit software
version.
SysSW: System base software
version.
BootSW: Boot software
version.
SW Item: Software item
number.
Serial: Device serial number.
Prog: Programmer name.
Date: Programming date.
6/22 Restore settings
ROBOT All settings All memory channels (0-199)
are restored from backup.
Setup settings remain as they
are.
Restore to factory All memory channels and
their backups are removed.
All settings are set to default