Operation Manual
20
A7 MIG Welder© Kemppi Oy 2018 1824
OPERATING MANUAL
Welding parameters for WiseRoot+ process (Edit channel 2/6)
Menu item Value range Default value Description
1/6 WFSpeed WFS min -
WFS max
From curve Set the wire feed speed in
0.05 m/min steps from 0.5
to 5.0 m/min and in 0.1 m/
min steps above 5.0 m/min.
2/6 WFS max 1.2 - 11.0 m/min * From curve Set the upper limit for the
WFSpeed value.
3/6 WFS min 1.2 - 11.0 m/min * From curve Set the lower limit for the
WFSpeed value.
4/6 FineTuning FineTuningMin -
FineTuningMax
0 Adjust the base current (arc
heat) of the curve up and
down (0 = no adjustment).
5/6 FineTuningMax -9.0 … +9.0 +9.0 Set the upper limit for the
FineTuning value.
6/6 FineTuningMin -9.0 … +9.0 -9.0 Set the lower limit for the
FineTuning value.
* These are system limits. Actual limits come from the selected welding curve.
Welding parameters for WiseThin+ process (Edit channel 2/6)
Menu item Value range Default value Description
1/7 WFSpeed WFS min -
WFS max
From curve Set the wire feed speed
in 0.05 m/min steps from
0.5 to 5.0 m/min and in
0.1 m/min steps above 5.0
m/min.
2/7 WFS max 0.7 - 25.0 m/min * From curve Set the upper limit for the
WFSpeed value.
3/7 WFS min 0.7 - 25.0 m/min * From curve Set the lower limit for the
WFSpeed value.
4/7 FineTuning FineTuningMin -
FineTuningMax
0 Adjust the base current
(arc heat) of the curve
up and down (0 = no
adjustment).
5/7 FineTuningMax -9.0 … +9.0 +9.0 Set the upper limit for the
FineTuning value.
6/7 FineTuningMin -9.0 … +9.0 -9.0 Set the lower limit for the
FineTuning value.
7/7 Dynamics -9 … +9 0 Control the arc behavior in
short circuit. A lower value
results in a softer arc and
a higher value results in a
rougher arc.
* These are system limits. Actual limits come from the selected welding curve.