Operation Manual

12
A7 MIG Gun 500-w© Kemppi Oy 2017 1712
OPERATING MANUAL
11.4 Connecting the gun system to the wire feeder
This section describes how to connect the gun system to the wire feeder.
Figure 7: Connecting the gun system to the wire feeder
4
5
8
Proceed as follows:
1. Check again that the wire guide has been attached correctly. See the gure
above.
2. Mount the central connector (5) on the wire feeder, and secure it with the
connection nut (4).
3. Fasten the air-blast hose (8) to the air-blast and spraying unit or the air-blast
valve. Seal the connection gas-tight if the "Air-blast" option will not be in use.
11.5 Connecting the coolant
This section describes how to connect the coolant.
Risk of burns
The A7 MIG Gun 500-w cable assembly will become overheated if the coolant level
is too low.
Wear protective gloves.
Check the coolant level at regular intervals.
Make sure that the coolant supply and return have been installed properly.
Coolant supply = blue, coolant return = red.
Do not use any de-ionized or de-mineralized water as coolant or for tightness or
ow tests. This may shorten the service life of your welding gun.
We recommend the use of a Kemppi-brand cooling liquid for liquid-cooled
welding guns.
Figure 8: Connecting the coolant
1
4
5
3
2
1. Control lead
2. Coolant ow hose
3. Compressed air hose
4. Coolant return hose
5. Cable assembly
Ventilate the entire cooling system before it is used for the rst time and after every cable
assembly change.
Proceed as follows:
1. Disconnect the coolant return hose (4) from the re-circulating cooling unit, and hold
it over a collecting device.
2. Close the opening at the coolant return hose (4), and open it again by abruptly
releasing it. Repeat this action until the coolant is owing into the collecting device
continuously and without air bubbles.
3. Switch o the re-circulating cooling unit, and reconnect the coolant return hose (4).