Instruction Manual
9
A7 Cooler© Kemppi Oy 2021 R01
OPERATING MANUAL
4. MAINTENANCE
Watch out for mains voltage when handling electric
cables!
In planning product maintenance machine utilization
degree and circumstances should be considered.
Careful use and preventive maintenance help to avoid
unnecessary production disturbances and breaks.
4.1 Daily maintenance
The following maintenance opeations should be carried
out daily:
• Check water level and input ow, add liquid if
needed.
• Check cables and connections. Tighten, if
necessary and replace defect parts.
• Check that there are no leakages in the cooling
water hoses.
4.2 Monthly maintenance
Check and clean the lter unit on the front panel once a
month:
1. Unscrew the cup from the lter and remove the
lter from the pivot.
2. Clean the lter net using water and compressed
air.
3. Replace the lter net and the cup.
4.3 Every sixth months
The following maintenance opeations should be carried
out at least every sixth months:
• Clean o dust and dirt. Change the cooling
liquid and wash up the pipes and water reservoir
with pure water.
• Check seals, cables and connections. Tighten, if
necessary and replace defect parts.