Operation Manual

32
A5 TIG Orbital System 75© Kemppi Oy 2016 1615
OPERATING MANUAL
Check at least every half year:
Electric connectors of the machine – clean any oxidized parts and tighten
loose connections.
Validate calibration of the weld head and controller according instructions
given in this manual.
Do not use compressed air for cleaning as there is a risk that the dirt will compact
even more tightly into gaps of cooling proles.
Do not use pressure washing devices.
Only an authorized trained electrician should carry out repairs to Kemppi machines.
6.3 Service Workshop maintenance
Kemppi Service Workshops complete maintenance according to their Kemppi service
agreement.
The major points in the maintenance procedure are listed as follows:
Cleaning of the machine
Checking and maintenance of the welding tools
Checking of connectors, switches and potentiometers
Checking of electric connections
Checking of mains cable and plug
Damaged parts or parts in bad condition are replaced by new ones
Maintenance testing.
Operation and performance values of the machine are checked, and when
necessary adjusted by means of software and test equipment.
Software loading
Kemppi Service Workshops can also test and load rmware and welding software.
7. DISPOSAL
Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic
equipment, and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and taken to an appropriate
environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional
collection center, as per the instructions of local authorities or a Kemppi representative.
By applying this European Directive you will improve the environment and human health.