Operation Manual
16
A5 TIG Orbital System 75© Kemppi Oy 2016 1615
OPERATING MANUAL
3.5.5 Weld Programs – selecting a weld program
1–10
Selected welding programs show on the top right corner
of the screen.
If a program is modied (for example, Program 2),
it can run in modied state without changing the stored
Program 2. As soon as the power is turned o, it stores the
screen parameters and overwrites the original Program 2.
When the same program is loaded from the memory (after
unsaved modications), the original saved program is
restored.
When controller unit’s power is turned on, it always
displays the last program run before power was turned o.
You can store programs on a memory stick using the
USB port and extend your number of stored programs.
3.5.6 Calibrating weld head or power source
output
1. On the Tool Box screen, press Calibration.
2. This screen indicates that you need to read the
manual before calibration.Continue by pressing the
check mark to display below screen.
3. Two modes are available:
• Checking Weld Head Rotation Speed
• Calibrating Weld Current Output
4. Check head rotation speed.
5. Connect the weld head to the controller and load a
program, or call up a stored program.
6. Press Head Rotation Speed Check
Pressing the Head Rotation Speed Check button starts
the rotor in the weld head to rotate without an arc. Keep
your hands clear from the rotor.
Previously selected program autogenerates a certain rpm
that is also shown as time in seconds for one revolution.
• Use a stopwatch or watch to check the actual
rotation time.
The rotor starts at Home position, travels 360°, and stops
when pressing Home. Actual rotation time should match
the calibrated time. The rotation motor is factory calibrated
and should not need recalibration.
• Contact Kemppi if the weld head has lost its
calibration.
6
3
2
1