Operation Manual
14
A5 TIG Orbital System 75© Kemppi Oy 2016 1615
OPERATING MANUAL
3.4 Weld head control panel
W009315
A
B
C
D
A. Stop: immediately terminate the weld cycle and all
functions of the weld head.
B. Start Weld: initiate the weld program. LED light
beside the button is lit during the weld cycle. This is
also a soft way to stop welding.
C. Home position: welding can be started only when
the rotor gear is in its home position. It also allows
easy installation and removal of the workpiece.
1. Press the Home button to move the rotor gear
to the home position.
2. A red LED ignites next to this button, when the
rotor gear reaches its home position.
D. Rotation forward or reverse: with these buttons you
can move the rotor gear to either direction when
welding arc is not on. This is useful when mounting
or replacing the electrode or checking its condition.
3.5 Controller unit control panel
3.5.1 Quick guide to start welding
A
1
5 0 0 0
mm
2
0 1 5 0
mm
3
1. Start from initial screen.
2. Set the tube’s OD size.
3. Set the tube’s wall thickness.
4. Press Start Weld button