5.2 Status functions
The status functions are bit elds (values) and single bits
(signals) in the I/O table. They are set by the welder system
and read by the robot.
Table 5.2 Status functions in the A3 MIG Welder system
Function Bits
Value range
Min.
Max.
Step
Units
Status values
WeldingCurrent 16 0 1000 1 1 A
WeldingVoltage 16 0 1000 1 0.1 V
ErrorNumber 8 0 255 1
Status signals
Ready 1
PowerSourceReady 1
CycleOn 1
ArcOn 1
TouchSensed 1
Error 1
CollisionDetected 1
5.2.1 WeldingCurrent
This 16-bit function represents the average welding
current measured during the process. The value is in
scaled or non-scaled mode, depending on the user setup.
In non-scaled mode:
The minimum value is 0 A.
The maximum value is 1000 A.
The minimum step is 1 A.
In scaled mode:
The minimum value is 0 (0 A).
The maximum value is the robot scaling value,
which is interpreted as 1000 A.
The minimum step is 1. The welding current is
calculated from the function value by means of
the value scaling formula.
5.2.2 WeldingVoltage
This 16-bit function represents the average welding
voltage measured during the process. The value is in
scaled or non-scaled mode, depending on the user setup.
In non-scaled mode:
The minimum value is 0 (0.0 V).
The maximum value is 1000 (100.0 V).
The minimum step is 1 (0.1 V).
In scaled mode:
The minimum value depends on the scaled value
range and is interpreted as 0.0 V.
The maximum value is the robot scaling value,
which is interpreted as 100.0 V.
The minimum step is 1. The welding voltage is
calculated from the function value by means of
the value scaling formula.