OPERATING MANUAL
4.7 Welding and system setup
Quick setup
To set the values of the functional parameters for MIG features, use the QUICK SETUP
feature, which you can activate by briey pressing the SETUP button (5).
Select the parameter to adjust using the left-hand side control knob or the button (8)
and then set the parameter value with the right-hand side control knob. The value you
specied is instantly stored in the control panel memory. The following tables list the
parameter values that can be specied for the MIG features.
QUICK SETUP, MIG
Parameter Display Value range Factory
setting
Description
Creep start
level
Cre
10 ... 170 % 50 % Percent of wire feed speed default
10% refers to slow start,
170% refers to fast start
QUICK SETUP, 1-MIG, WiseThin, WiseRoot
Parameter Display Value range Factory
setting
Description
Creep start
level
Cre
10 ... 170 % 50 % Percent of wire feed speed default
10% refers to slow start,
170% refers to fast start
Hot start
level
Hot
-50 ... 75 % 30 % Percent of welding power:
-50% refers to cold start
+75% refers to hot start
Hot start time
H2t
0 ... 9.9 s 1.2 s The duration of the hot start in seconds.
Crater ll
start level
CrS
Crater ll
end level ...
250 %
90 % The welding power at the beginning of
the crater ll stage as a percentage of
the welding power pre-set value.
Crater ll end
level
CrL
10 ... Crater
ll start level
30 % The welding power at the end of the
crater ll stage as a percentage of the
welding power pre-set value.
Crater ll
time
Crt
0 ... 9.9 s 2 s The duration of the crater ll stage in
seconds.
All setup parameters
The machine has several parameters, whose settings can be specied with the control
panel's SETUP function as follows:
1. Press and hold down the SETUP button (5) for at least 5 seconds.
2. Select the parameter to adjust using the left-hand side control knob. The parameter
name is shown in display left-hand display.
3. Specify the parameter value with the right-hand side control knob. The selected
value is shown in the right-hand display. The parameter’s value is immediately
stored in the memory.
4. Exit the SETUP mode by pressing and holding down the SETUP button again for at
least 5 seconds or by briey pressing the ESC button.
All welding processes have their own setup parameters. For example, adjusting the post-
current for synergic MIG welding does not aect the post-current of normal MIG weld-
ing.
The tables below show the features available in this welding machine and their possible
values.