User Manual
MIDI PARAMETER DOCUMENTATION 68
$B0,$63,Address Number
$B0,$06,Parameter Value
$B0 is the Midi Start Byte for controllers at Midi Channel 0.
The Kemper Profiling Amplifier will listen to the Midi Channel that is set as the Midi Global Channel in the
System Menu.
The standard setting is “Omni”, saying it responds to every channel.
There is two types of parameters in the Kemper Profiling Amplifier and their properties:
Continuous Parameters (like Gain, Volume,)
- Are fractional numbers and Will always cover the whole value range
- Will be smoothed upon reception of multiple continuous values. Thus, high resolution (14 bit) values are
not necessary for a smooth parameter movement, only for accurate target values.
Switch or Section Parameters (like Type, On/O)
- Are integer numbers and will start counting from the least significant bit.
- That is the LSBit of controller #38, when sent for high resolution, or the LSBit of controller #6, when #38
is left out for low resolution.
- Values out of range will activate the highest value in the range, but should not be used due to future
compatibility
- Switches are “O” at the value zero and “On” at all nonzero values.
Rig
Address Page 4
0 Rig Tempo
1 Rig Volume
2 Rig Tempo Enable
Input
Address Page 9
3 Noise Gate Intensity