User Manual
KEMPER PROFILING AMPLIFIER52
The Volume pedal does not have its own eect type, as this would block a stomp or eect slot every time
you wanted to use the pedal. Instead, you will find two parameters for the Volume Pedal in the RIG menu.
Volume pedal position
Selects the position of the volume pedal in the signal flow:
O The volume pedal has no eect
Pre-stomps Directly before STOMP A
Post-stomps Right after STOMP D. At this position you control the gain of the amplifier.
Pre-eects Right before STOMP X. At this position you control the overall volume of the sound, but
delay and reverb tails will still decay naturally, when you swell down the pedal.
Post-eects Right after the reverb. At this position you control the overall volume of the sound,
including reverb and delay tails, that can instantly be attenuated.
Volume pedal range
This is a bipolar parameter. In the middle position, the volume pedal has no eect. When you set the range
more to the left, you determine the minimum volume at heal-position, while the maximum volume at toe-
position stays the same. At the minimum position, the pedal performs the swell from zero level, just as you
would expect from an analog volume pedal. When you turn “Volume Pedal Range” to the left half, the vol-
ume pedal turns from an attenuation pedal into a booster pedal. Now, the heel stays at standard volume,
and the toe-swell will give you a volume or gain boost. The maximum boost, at the top position of “Volume
Pedal Range”, is +24 dB.