User Manual

Table Of Contents
Instrument Input and Reamping 118
Alternative Procedure for Input Leveling
The original "Clean Sens" leveling from step two, and the final leveling of "Reamp Sens" have a kind of opposite
relationship that can be used for easier and safer leveling, under two conditions:
The Rig in question is a distorting one.
You have memorized the original Clean Sens setting used to record the pure instrument.
First, set "Reamp Sens" to the opposite value of the original "Clean Sens" setting (e.g. 2.0 dB, when Clean Sens
was -2.0 dB). Now, level the desired amount of distortion by adjusting the output volume on the recording device.
Once this is done, you will have found the correct input level by default. There is no need to watch the INPUT LED
with this procedure.