8 specifications/installation Kelvinator Air Conditioning
less than 220mm
less than 220mm
more than
60mm
more
than
150mm
more than 500mm
wall thickness is less than 220mm
make rear of the airconditioner (outside)
lower than the front of the airconditioner
(inside) to allow water to drain
5-10mm
scrape
45°
if the wall thickness is more than 220mm
scrape the wall as shown above
Specifications
Unit dimensions:
Model (kW)
Body dimension (mm)
(WxHxD)
< 1.5kW
452x342x550
Suggest minimum wire size (AWG:American Wire Gage):
Appliance Amps AWG Wire Size
10
18
Installation
Select the best location
1 To avoid vibration and noise, make sure the unit is
installed securely and firmly.
2 Install the unit where the sunlight does not shine directly
on the unit.
If the unit receives direct sunlight, build an awning to
shade the cabinet.
3 There should be no obstacle, such as a fence or wall,
within 50cm from the back of the cabinet because it will
prevent heat radiation of the condensor.
Restriction of outside air will greatly reduce the cooling
and heating efficiency of the air conditioner.
4 Install the unit a little obliquely outward not to leak the
condensed water into the room (about 10mm or 1/4
bubble with level).
5 Install the unit with its bottom portion 75~150cm above
the floor level.
6 The power cord must be connected to an independent
circuit. The yellow/green wire must be grounded.
7 Based on calculations in compliance with AS60335.2.40
there is no minimum safe floor area for the installation of
the air conditioners described in this manual.
8 After installation the power plug should be easily
accessible.
more
than
150mm