Installation Guide
24 Kelvinator Air Conditioning Installation instructions
Testing the air conditioner
Soapy water method
Apply soapy water or liquid neutral detergent on all valves 
and pipe connections (A, B, C and D, refer to the figure 
below) involved in installation by a soft brush to check for 
leakage. If bubbles come out, the pipes have leakage.
outdoor  
unit
2-way 
valve
3-way 
valve
indoor check points
suction pipe 
(discharge pipe  
for KSV53HRE 
and KSV62HRE)
outdoor check 
points
B
D
C
A
discharge pipe 
(suction pipe for 
KSV53HRE and 
KSV62HRE)
Leak detector
Use the leak detector to check for leakage.
Electrical safety check
Perform the electric safety check after completing the 
installation:
1  Earthing work
  After finishing earthing work, measure the earthing 
resistance by visual detection and earthing resistance 
tester.
2  Electrical leakage check (perform while the test is 
running)
  During test operation after finishing the installation, the 
service person can use the electric probe and multimeter  
to perform the electrical leakage check. Turn off the unit  
immediately if refrigerant leakage happens. Check and 
find out the solution ways until the unit operates properly.
Operation test
1  Before operation test
•  Do not switch on power before installation is nished  
 completely.
•  Electric wiring must be connected correctly and securely.
•  Stop valves of the connection pipes should be fully  
 opened.
•  All the impurities such as scraps and waste must be 
cleared from the unit.
Operation test method
•  Switch on power and press “ON/OFF” button on the 
remote controller to start the operation. Press MODE 
button to select the COOL, HEAT  
(if applicable), FAN to check if all the functions work well.
•  When the ambient temperature is lower than 16°C), 
the unit can not be set on the remote control to work 
in COOL mode. Please use the Emergency Operation 
mode which is used only when the remote is unavailable 
or in case of maintenance.
manual control 
button
manual control button
Pump down
When relocating or disposing of the air conditioner, pump 
down the system following the procedure below so that no 
refrigerant is released into the atmosphere.
•  Connect the hose of manifold valve to the charge port of 
stop valve on the gas pipe side of the outdoor unit.
•  Close the stop valve on the gas pipe side almost 
completely.
•  Fully close the stop valve on the liquid pipe side.
•  Turn on the unit in COOL mode.
•  Fully close the stop valve on the gas pipe side when the 
pressure gauge shows 1 - 0.5 kgf/cm (100 ~ 50 kPa).
•  Stop the test run operation by turning the unit off and  
all the refrigerant gases have been collected in the 
outdoor unit.