Installation Guide

23
s !LLGASPIPINGMUSTBEINSTALLEDINCOMPLIANCEWITH
LOCALCODESANDUTILITYREGULATIONS)NTHEABSENCE
OFLOCALCODESTHEGASLINEINSTALLATIONMUSTCOMPLY
WITHTHELATESTEDITIONOFTHE.ATIONAL&UEL'AS#ODE
!.3):OR#!.#'!"OR)NSTALLATION
Codes.
s 3OME LOCAL REGULATIONS REQUIRE THE INSTALLATION
OFAMANUALMAINSHUTOFFVALVEANDGROUNDJOINT
UNIONEXTERNALTOTHEFURNACEASSHOWNINFigure
 PAGE 25 & &IGURE  PAGE 26 4HE SHUT
OFFVALVESHOULDBEREADILYACCESSIBLEFORSERVICE
ANDOREMERGENCYUSE#ONSULTTHELOCALUTILITYOR
GASSUPPLIERFORADDITIONALREQUIREMENTSREGARDING
PLACEMENTOFTHEMANUALMAINGASSHUTOFF
s 'ASPIPINGMUSTNEVERRUNINORTHROUGHAIRDUCTS
CHIMNEYSGASVENTSORELEVATORSHAFTS
s #OMPOUNDSUSEDONTHREADEDJOINTSOFGASPIPING
MUSTBERESISTANTTOTHEACTIONSOF,0PROPANEGAS
s 4HEMAINGASVALVEANDMAINPOWERDISCONNECTTO
THEFURNACEMUSTBEPROPERLYLABELEDBYTHEINSTALLER
INCASEEMERGENCYSHUTDOWNISREQUIRED
s &LEXIBLEGASCONNECTORSARENOTRECOMMENDEDFOR
THISTYPEOFFURNACEBUTMAYBEUSEDIFALLOWEDBY
LOCAL JURISDICTION /NLY NEW mEXIBLE CONNECTORS
MAYBEUSED$ONOTUSEACONNECTORWHICHHAS
PREVIOUSLYSERVICEDANOTHERGASAPPLIANCE
s !DRIPLEGSHOULDBEINSTALLEDINTHEVERTICALPIPE
RUNTOTHEUNIT3EEFigure 25 or Figure 26.
Table 11 (page 40) lists gas flow capacities for standard
pipe sizes as a function of length in typical applications
based on nominal pressure drop in the line.
The furnace may be installed with either left or right side
gas entry. When connecting the gas supply, provide
clearance between the gas supply line and the entry hole
in the furnace casing to avoid unwanted noise and/or
damage to the furnace. Typical gas hookups are shown
in Figure 25 & Figure 26.
,EAK#HECK
FIRE OR EXPLOSION HAZARD
s &AILURE TO FOLLOW SAFETY WARNINGS EXACTLY
COULD RESULT IN SERIOUS INJURY OR PROPERTY
DAMAGE
s )NSTALLATIONANDSERVICEMUSTBEPERFORMED
BYAQUALIlEDINSTALLERSERVICEAGENCYORTHE
GASSUPPLIER
s $O NOT STORE OR USE GASOLINE OR OTHER
mAMMABLEVAPORSANDLIQUIDSINTHEVICINITY
OFTHISORANYOTHERAPPLIANCE
WHAT TO DO IF YOU SMELL GAS
s $ONOTTRYTOLIGHTANYAPPLIANCE
s $ONOTTOUCHANYELECTRICALSWITCHDONOT
USEANYPHONEINYOURBUILDING
s ,EAVETHEBUILDINGIMMEDIATELY
s )MMEDIATELYCALLYOURGASSUPPLIERFROMA
NEIGHBORSPHONE&OLLOWTHEGASSUPPLIERS
instructions.
s )FYOUCANNOTREACHYOURGASSUPPLIERCALL
THElREDEPARTMENT
WARNING:
2)315%$).#%.$)%/5$%80,/3)/.
s ,E NONRESPECT DES AVERTISSEMENTS DE
SÏCURITÏ POURRAIT ENTRAÔNER DES BLESSURES
GRAVESLAMORTOUDESDOMMAGESMATÏRIELS
s ,INSTALLATION ET LENTRETIEN DOIVENT ÐTRE
EFFECTUÏS PAR UN INSTALLATEUR QUALIlÏ UN
ORGANISME DE SERVICE OU LE FOURNISSEUR
DE GAZSTALLER SERVICE AGENCY OR THE GAS
SUPPLIER
s .EPASENTREPOSERNIUTILISERDELESSENCENI
DAUTRESVAPEURSOULIQUIDESINmAMMABLES
DANSLEVOISINAGEDECETAPPAREILNIDETOUT
AUTREAPPAREIL
15%&!)2%3),9!5.%/$%52$%'!:
s .EPASTENTERDALLUMERAUCUNAPPAREIL
s .ETOUCHERËAUCUNINTERRUPTEURÏLECTRIQUE
NUTILISERAUCUNTÏLÏPHONEDANSLEBÉTIMENT
s ²VACUERLIMMEUBLEIMMÏDIATEMENT
s !PPELER IMMÏDIATEMENT LE FOURNISSEUR DE
GAZENEMPLOYANTLETÏLÏPHONEDUNVOISIN
2ESPECTER Ë LA LETTRE LES INSTRUCTIONS DU
FOURNISSEURDEGAZ
s 3IPERSONNENERÏPONDAPPELERLESERVICE
des incendies.
AVERTISSEMENT:
GAS SUPPLY & PIPING
FIRE OR EXPLOSION HAZARD
&AILURETOFOLLOWSAFETYWARNINGSEXACTLYCOULD
RESULTINSERIOUSINJURYORPROPERTYDAMAGE
.EVERTESTFORGASLEAKSWITHANOPENmAME
5SEACOMMERCIALLYAVAILABLESOAP SOLUTION
MADE SPECIlCALLYFORTHEDETECTION OF LEAKS
TOCHECKALLCONNECTIONS!lREOREXPLOSION
MAYRESULTCAUSINGPROPERTYDAMAGEPERSONAL
INJURYORLOSSOFLIFE
WARNING: