COMBUSTION AIR & VENTING REQUIREMENTS
CARBON MONOXIDE POISONING HAZARD
&AILURE TO FOLLOW THE STEPS OUTLINED BELOW
FOREACHAPPLIANCECONNECTEDTOTHEVENTING
SYSTEM BEING PLACED INTO OPERATION COULD
RESULTINCARBONMONOXIDEPOISONINGORDEATH
4HEFOLLOWING STEPS SHALL BE FOLLOWEDWITH
EACHINDIVIDUALAPPLIANCECONNECTEDTOTHE
VENTING SYSTEM BEING PLACED IN OPERATION
WHILEALLOTHERAPPLIANCESCONNECTEDTOTHE
VENTINGSYSTEMARENOTINOPERATION
3EALANYUNUSEDOPENINGSINTHEVENTINGSYSTEM
)NSPECTTHEVENTINGSYSTEMFORPROPERSIZEAND
HORIZONTALPITCHASREQUIREDINTHENational Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the CSA
B149.1, Natural Gas and Propane Installation
Codes
ANDTHESEINSTRUCTIONS$ETERMINETHAT
THERE IS NO BLOCKAGE OR RESTRICTION LEAKAGE
CORROSIONANDOTHERDElCIENCIESWHICHCOULD
CAUSEANUNSAFECONDITION
!SFARASPRACTICALCLOSEALLBUILDINGDOORSAND
WINDOWSANDALLDOORSBETWEENTHESPACEIN
WHICHTHEAPPLIANCESCONNECTEDTOTHEVENTING
SYSTEM ARE LOCATED AND OTHER SPACES OF THE
BUILDING
#LOSElREPLACEDAMPERS
4URNONCLOTHESDRYERSANDANYAPPLIANCENOT
CONNECTEDTOTHEVENTINGSYSTEM4URNONANY
EXHAUSTFANSSUCHASRANGEHOODSANDBATHROOM
EXHAUSTSSOTHEYARE OPERATINGAT MAXIMUM
SPEED$ONOTOPERATEASUMMEREXHAUSTFAN
&OLLOW THE LIGHTING INSTRUCTIONS 0LACE THE
APPLIANCE BEING INSPECTED INTO OPERATION
!DJUSTTHETHERMOSTATSOAPPLIANCEISOPERATING
CONTINUOUSLY
4EST FOR SPILLAGE FROM DRAFT HOOD EQUIPPED
APPLIANCESATTHEDRAFTHOODRELIEFOPENINGAFTER
MINUTES OF MAINBURNEROPERATION5SE THE
mAMEOFAMATCHORCANDLE
)FIMPROPERVENTINGISOBSERVEDDURINGANYOF
THEABOVETESTSTHEVENTINGSYSTEMMUSTBE
CORRECTEDINACCORDANCEWITHTHENational Fuel
Gas Code, ANSI Z223.1/NFPA 54 and/or CSA
B149.1, Natural Gas and Propane Installation
Codes.
!FTERITHASBEENDETERMINEDTHATEACHAPPLIANCE
CONNECTEDTOTHEVENTINGSYSTEMPROPERLYVENTS
WHENTESTEDASOUTLINEDABOVERETURNDOORS
WINDOWSEXHAUSTFANSlREPLACEDAMPERSAND
ANYOTHERGASlREDBURNINGAPPLIANCETOTHEIR
PREVIOUSCONDITIONSOFUSE
WARNING:
2)315%$%-0/)3/..%-%.4!5
MONOXYDE DE CARBONED
,ENONRESPECT DESCONSIGNESSUIVANTESPORTANT
SURCHACUN DESAPPAREILS RACCORDÏSAU SYSTÒME
DÏVACUATION MIS EN SERVICE POURRAIT ENTRAÔNER
LEMPOISENNEMENT AU MONOXYDE DE CARBONE OU
LA MORT ,ES CONSIGNES SUIVANTES DOIVENT ÐTRE
OBSERVÏES POUR CHAQUE APPAREIL RACCORDÏ AU
SYSTÒMEDÏVACUATIONMISENSERVICESILESAUTRES
APPAREILS RACCORDÏS AU SYSTÒME NE SONT PAS EN
SERVICE
3CELLERTOUTEOUVERTURENONUTILISÏEDELASYSTÏME
DÏVACUATION
3ASSURERQUELASYSTÏMEDÏVACUATIONPRÏSENTEDES
DIMENSIONSETUNEPENTEHORIZONTALECONFORMESËLA
NORME!.3):.&0!INTITULÏE.ATIONAL&UEL
'AS#ODEOUAUXCODESDINSTALLATION#3!"
AINSIQUAUXPRÏSENTESINSTRUCTIONS3ASSURERQUELA
SYSTÏMEDÏVACUATIONNESTPASBLOQUÏERESTREINTE
CORRODÏEQUELLENEFUITPASETQUELLENEPRÏSENTE
AUCUNAUTREDÏFAUTPOTENTIELLEMENTDANGEREUX
$ANSLAMESUREDUPOSSIBLEFERMERTOUTESLESPORTES
ETFENÐTRESDUBÉTIMENTETTOUTESLESPORTESENTRELA
PIÒCEOáSETROUVELAPPAREILRACCORDÏËLASYSTÏME
DÏVACUATIONETLESAUTRESPIÒCESDUBÉTIMENT
&ERMERLESREGISTRESDESFOYERS
-ETTREENSERVICELESSÏCHEUSESETTOUTAUTREAPPAREIL
QUINESTPASRACCORDÏËLASYSTÏMEDÏVACUATION
&AIREFONCTIONNERËRÏGIMEMAXIMALTOUTVENTILATEUR
DÏVACUATIONTELQUELESHOTTESDECUISINIÒREETLES
VENTILATEURSDESALLESDEBAINS.EPASMETTREEN
SERVICELESVENTILATEURSDÏTÏ
2ESPECTERLESINSTRUCTIONSDALLUMAGE-ETTREEN
SERVICE LAPPAREIL Ë LESSAI 2ÏGLER LE THERMOSTAT
DE MANIÒRE Ë CE QUE LAPPAREIL FONCTIONNE SANS
INTERRUPTION
6ÏRIlERSILYADÏBORDEMENTËLORIlCEDÏVACUATION
DUCOUPETIRAGEDESAPPAREILSDOTÏSDUNCOUPE
TIRAGE MINUTES APRÒS LALLUMAGE DU BRßLEUR
PRINCIPAL 5TILISER LA mAMME DUNE ALLUMETTE OU
DUNECHANDELLE
3ILONCONSTATEAUCOURSDELUNDESESSAISQUI
PRÏCÒDENTQUELÏVACUATIONESTDÏlCIENTECORRIGER
LESYSTÒMEDÏVACUATIONCONFORMÏMENTËLANORM
!.3):.&0!.ATIONAL&UEL'AS#ODEET
OUAUXCODESDINSTALLATION#3!"
!PRÒS AVOIR DÏTERMINÏ QUE TOUS LES APPAREILS
RACCORDÏS Ë LA SYSTÏME DÏVACUATION ÏVACUENT
CORRECTEMENTTELQUEPRESCRITCIDESSUSROUVRIRLES
PORTESETLESFENÐTRESETREMETTRELESVENTILATEURS
DÏVACUATION LES REGISTRES DE FOYERS ET TOUT
AUTREAPPAREILFONCTIONNANTAUGAZËLEURÏTATDE
FONCTIONNEMENTINITIAL
AVERTISSEMENT: