Installation Guide
23
s !LLGASPIPINGMUSTBEINSTALLEDINCOMPLIANCEWITH
LOCALCODESANDUTILITYREGULATIONS)NTHEABSENCE
OFLOCALCODESTHEGASLINEINSTALLATIONMUSTCOMPLY
WITHTHELATESTEDITIONOFTHE.ATIONAL&UEL'AS#ODE
!.3):OR#!.#'!"OR)NSTALLATION
Codes.
s 3OME LOCAL REGULATIONS REQUIRE THE INSTALLATION
OFAMANUALMAINSHUTOFFVALVEANDGROUNDJOINT
UNIONEXTERNALTOTHEFURNACEASSHOWNINFigure
PAGE 25 & &IGURE PAGE 26 4HE SHUT
OFFVALVESHOULDBEREADILYACCESSIBLEFORSERVICE
ANDOREMERGENCYUSE#ONSULTTHELOCALUTILITYOR
GASSUPPLIERFORADDITIONALREQUIREMENTSREGARDING
PLACEMENTOFTHEMANUALMAINGASSHUTOFF
s 'ASPIPINGMUSTNEVERRUNINORTHROUGHAIRDUCTS
CHIMNEYSGASVENTSORELEVATORSHAFTS
s #OMPOUNDSUSEDONTHREADEDJOINTSOFGASPIPING
MUSTBERESISTANTTOTHEACTIONSOF,0PROPANEGAS
s 4HEMAINGASVALVEANDMAINPOWERDISCONNECTTO
THEFURNACEMUSTBEPROPERLYLABELEDBYTHEINSTALLER
INCASEEMERGENCYSHUTDOWNISREQUIRED
s &LEXIBLEGASCONNECTORSARENOTRECOMMENDEDFOR
THISTYPEOFFURNACEBUTMAYBEUSEDIFALLOWEDBY
LOCAL JURISDICTION /NLY NEW mEXIBLE CONNECTORS
MAYBEUSED$ONOTUSEACONNECTORWHICHHAS
PREVIOUSLYSERVICEDANOTHERGASAPPLIANCE
s !DRIPLEGSHOULDBEINSTALLEDINTHEVERTICALPIPE
RUNTOTHEUNIT3EEFigure 25 or Figure 26.
Table 11 (page 40) lists gas flow capacities for standard
pipe sizes as a function of length in typical applications
based on nominal pressure drop in the line.
The furnace may be installed with either left or right side
gas entry. When connecting the gas supply, provide
clearance between the gas supply line and the entry hole
in the furnace casing to avoid unwanted noise and/or
damage to the furnace. Typical gas hookups are shown
in Figure 25 & Figure 26.
,EAK#HECK
FIRE OR EXPLOSION HAZARD
s &AILURE TO FOLLOW SAFETY WARNINGS EXACTLY
COULD RESULT IN SERIOUS INJURY OR PROPERTY
DAMAGE
s )NSTALLATIONANDSERVICEMUSTBEPERFORMED
BYAQUALIlEDINSTALLERSERVICEAGENCYORTHE
GASSUPPLIER
s $O NOT STORE OR USE GASOLINE OR OTHER
mAMMABLEVAPORSANDLIQUIDSINTHEVICINITY
OFTHISORANYOTHERAPPLIANCE
WHAT TO DO IF YOU SMELL GAS
s $ONOTTRYTOLIGHTANYAPPLIANCE
s $ONOTTOUCHANYELECTRICALSWITCHDONOT
USEANYPHONEINYOURBUILDING
s ,EAVETHEBUILDINGIMMEDIATELY
s )MMEDIATELYCALLYOURGASSUPPLIERFROMA
NEIGHBORSPHONE&OLLOWTHEGASSUPPLIERS
instructions.
s )FYOUCANNOTREACHYOURGASSUPPLIERCALL
THElREDEPARTMENT
WARNING:
2)315%$).#%.$)%/5$%80,/3)/.
s ,E NONRESPECT DES AVERTISSEMENTS DE
SÏCURITÏ POURRAIT ENTRAÔNER DES BLESSURES
GRAVESLAMORTOUDESDOMMAGESMATÏRIELS
s ,INSTALLATION ET LENTRETIEN DOIVENT ÐTRE
EFFECTUÏS PAR UN INSTALLATEUR QUALIlÏ UN
ORGANISME DE SERVICE OU LE FOURNISSEUR
DE GAZSTALLER SERVICE AGENCY OR THE GAS
SUPPLIER
s .EPASENTREPOSERNIUTILISERDELESSENCENI
DAUTRESVAPEURSOULIQUIDESINmAMMABLES
DANSLEVOISINAGEDECETAPPAREILNIDETOUT
AUTREAPPAREIL
15%&!)2%3),9!5.%/$%52$%'!:
s .EPASTENTERDALLUMERAUCUNAPPAREIL
s .ETOUCHERËAUCUNINTERRUPTEURÏLECTRIQUE
NUTILISERAUCUNTÏLÏPHONEDANSLEBÉTIMENT
s ²VACUERLIMMEUBLEIMMÏDIATEMENT
s !PPELER IMMÏDIATEMENT LE FOURNISSEUR DE
GAZENEMPLOYANTLETÏLÏPHONEDUNVOISIN
2ESPECTER Ë LA LETTRE LES INSTRUCTIONS DU
FOURNISSEURDEGAZ
s 3IPERSONNENERÏPONDAPPELERLESERVICE
des incendies.
AVERTISSEMENT:
GAS SUPPLY & PIPING
FIRE OR EXPLOSION HAZARD
&AILURETOFOLLOWSAFETYWARNINGSEXACTLYCOULD
RESULTINSERIOUSINJURYORPROPERTYDAMAGE
.EVERTESTFORGASLEAKSWITHANOPENmAME
5SEACOMMERCIALLYAVAILABLESOAP SOLUTION
MADE SPECIlCALLYFORTHEDETECTION OF LEAKS
TOCHECKALLCONNECTIONS!lREOREXPLOSION
MAYRESULTCAUSINGPROPERTYDAMAGEPERSONAL
INJURYORLOSSOFLIFE
WARNING: