Installation Guide
27
• Electricalconnectionsmustbeincompliancewithall
applicable local codes with the current revision of the
National Electric Code (ANSI/NFPA 70).
• ForCanadian installations the electrical connections
and grounding shall comply with the current Canadian
Electrical Code (CSA C22.1 and/or local codes).
IMPORTANTNOTE: Ifreplacing anyofthe original
wiressuppliedwiththefurnace,thereplacementwire
mustbecopperwiringandhaveatemperaturerating
ofatleast105°F(40°C).Forelectricalspecications,
refertothefurnacenameplateorTable5(page28).
ConversiontoLP/Propane
WARNING:
The furnace was shipped from the factory
equippedtooperateonnaturalgas.Conversion
to LP / Propane gas must be performed by
qualied service personnel using a factory
supplied conversion kit. Failure to use the
properconversionkitcancausere,explosion,
propertydamage,carbonmonoxidepoisoning,
personalinjury,ordeath.
Conversion to LP / Propane is detailed in the installation
instructions provided with the conversion kit. Generally,
this will require the replacement of the burner orifices and
the spring found under the cap screw on the pressure
regulator. In the U.S. if installation is above 2,000 ft., refer
to Table 12 (page 41) to determine the correct orifice size
and regulator pressure. See example below.
ELECTRICALSHOCK,FIREOREXPLOSION
HAZARD
Failuretofollowsafetywarningsexactlycould
resultinseriousinjuryorpropertydamage.
Improperservicingcouldresultindangerous
operation,seriousinjury,deathorproperty
damage.
• Beforeservicing,disconnect all electrical
powertofurnace.
• Whenservicingcontrols,labelallwiresprior
todisconnecting.Reconnectwirescorrectly.
• Verifyproperoperationafterservicing.”
WARNING:
RISQUEDECHOCÉLECTRIQUE,D’INCENDIE
OUD’EXPLOSION
Le non-respect des avertissements de sécurité
pourraitentraîner
unfonctionnementdangereux
del’appareil,
desblessuresgraves,lamortou
desdommagesmatériels.
Unentretein incorrectpourraitentraînerun
fonctionnementdangereuxdel’appareil,des
blessuresgraves,lamortoudesdommages
matériels
• Couper toute alimentation électrique au
générateurd’airchaudavantdeprodéder
auxtravauxd’entretein.
• Aumomentdel’entretiendescommandes,
étiqueteztousleslsavantdelesdébrancher.
S’assurerdelesraccordercorrectement.
•S’assurer que l’appareil fonctionne
adéquatementaprésl’entretien.
AVERTISSEMENT:
ELECTRICAL WIRING
InstallationExample
Elevation: ............................................. 5,000 feet
TypeofGas: ................................... Propane Gas
InputBTUHofFurnace: .......................... 72,000
From Table 12, find 5,000 and follow across the row,
stop at the 72,000 feet column. The manifold pressure
listed is 10.0 and the orifice size is 57.
When conversion is complete, verify the manifold pressure
and input rate are correct as listed in the table. Approved
conversion kits are listed below:
• TheUnitedStatesLP/PropaneGasSeaLeveland
High Altitude Conversion Kit (P/N 904914) is for LP /
Propane conversion in the United States at altitudes
between 2,000 ft. and 10,000 ft. above sea level. Please
followtheinstructionsprovidedwiththekit.
• TheCanadianLP/PropaneGasSeaLevelandHigh
Altitude Conversion Kit (P/N 904915) is for LP / Propane
conversions in Canada at altitudes between zero and
4,500 ft. above sea level. Pleasefollowtheinstructions
providedwiththekit.