Specification
6
BLOWER PERFORMANCE - KG7SL
Model
Number
Heating
External Static Pressure (Inches Water Column)
Input Motor 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
(Btuh) Speed
CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise
HIGH* 1580 29 1550 30 1520 30 1485 31 1460 32 1425 32 1375 33 1320 35
SL054D-24B 54,000 MED-HIGH 1240 37 1230 37 1210 38 1185 39 1165 39 1135 41 1100 42 1045 44
MED-LOW** 1145 40 1120 41 1100 42 1080 43 1055 44 1030 45 985 47 940 49
LOW 895 51 870 53 850 54 825 56 800 58 770 60 740 62 715 64
HIGH* 1560 39 1530 40 1500 41 1480 41 1435 43 1400 44 1360 45 1310 47
SL072D-24B 72,000 MED-HIGH** 1245 49 1225 50 1205 51 1180 52 1150 53 1125 55 1090 56 1045 59
MED-LOW 1085 57 1070 57 1045 59 1025 60 1000 61 970 63 930 66 880 70
LOW 850 72 830 74 800 77 780 79 760 81 730 84 710 86 685 90
HIGH* 1955 39 1905 40 1835 42 1795 43 1730 44 1620 47 1545 50 1450 53
SL090D-35C 90,000 MED-HIGH** 1845 42 1790 43 1750 44 1680 46 1515 51 1540 50 1475 52 1410 54
MED-LOW 1320 58 1290 59 1250 61 1215 63 1180 65 1120 68 1050 73 970 79
LOW 1190 64 1165 66 1125 68 1080 71 1055 73 1000 77 945 81 875 88
HIGH* 2215 46 2150 48 2075 49 2035 50 1970 52 1905 54 1800 57 1745 59
SL120D-45D 120,000 MED-HIGH** 2050 50 2015 51 1955 52 1900 54 1860 55 1795 57 1720 59 1620 63
MED-LOW 1720 59 1690 60 1655 62 1640 62 1610 63 1560 66 1505 68 1465 70
LOW 1420 72 1410 72 1400 73 1365 75 1350 76 1335 77 1290 79 1260 81
* Factory Set Cooling Speed NOTE: 1. Temperature rises in the table are approximate. Actual temperature rises may vary.
** Factory Set Heating Speed 2. Temperature rises shaded grey are for reference only. These conditions are not recommended.