Installation Guide
34
TROUBLESHOOTING
Ifthefurnacefailstooperatecheckthefollowing:
• Isthethermostatoperatingproperly?
• Aretheblowercompartmentdoor(s)inplace?
• Isthefurnacedisconnectclosed?
• Hasthecircuitbreakertrippedorthecontrolboardfuse
burnedopen?
• Isthegasturnedon?
• Areanymanualresetswitchesopen?
• Isthelterdirtyorplugged?
• Istheamesensorcoated?(Removeandcleanwith
steel wool).
• ArealltheLED’sonthefurnacecontrolboardconstantly
ON?Ifnot,refertoTable11orthewiringdiagram(Figure
19, page 30) to determine fault condition.
IMPORTANTNOTE:Thefurnacewilllockoutafter5
failedattemptsforignitionandwilltryagainevery
hourifthecallforheatremains.
• Iftheinducerblowerisoperatinganditemsabovehave
been verified, check the blower limit switch and reset
if necessary. See Figure 20 (page 35) for component
location.
DiagnosticDescription Green LED RedLED
Control Fault (No Power) Off Off
L1/Neutral Polarity Fault Flash Flash
1 Hour Lockout Alternating Flash
Normal Operation On On
Pressure Switch Closed Fault On Flash
Pressure Switch Open Fault Flash On
Open Limit Switch Fault Flash Off
Motor Fault On Off
DiagnosticDescription YellowLED
Low Flame Sensor Signal Continuous Flash
Flame Present On
Table11.ControlBoardFaultConditions
• Ifthefurnaceoperateswhentheblowerlimitswitchis
reset, contact a qualified service technician to identify
and repair the problem.
• If the furnace still doesn’t operate, check the ame
roll-out switch and reset if necessary. See Figure 20
for component location.
• Ifthefurnaceoperateswhentheamerolloutswitchis
reset, contact a qualified service technician to identify
and repair the problem.
FURNACE COMpONENTS
The descriptions below are various functional components that affect the operation and shutting down of this furnace.
Some of these components and their locations are shown in Figure 20 (page 35). If any component of the furnace must
be replaced, use only factory authorized replacement parts specified in the Replacement Parts List provided online.
BlowerLimitSwitch- Prevents operation when blower is not operational.
FlameSensor-Verifies when a flame has carried over from the igniter to the opposite end burner. If no flame is
detected, the furnace will shut down within 4 seconds.
FlameRoll-OutSwitch- Verifies that the burner flames are drawn into the heat exchanger tubes. If the burner
flames are not properly drawn into the heat exchanger, the flame roll-out switch will close the gas valve and initiate
the shutdown cycle.
GasValve-Controls the flow of gas to the burners. When the gas valve is energized it automatically opens and
regulates the gas pressure in the manifold.
InducerAssembly-Vents products of combustion to the outside.
PressureSwitch-Verifies that the inducer is drawing the combustion gases through the heat exchanger. The
pressure switch prevents furnace operation with excessive flue blockage or improper inducer operation.
SupplyAirLimitSwitch- Prevents the air temperature leaving the furnace from exceeding the maximum allowable
outlet air temperature.