Installation Guide
24
FanMode
• When the thermostat energizes the G terminal for
continuous fan (without calling for heat or cooling), the
indoor fan is energized on the selected FAN speed.
• Ifacallforcoolingoccursduringcontinuousfan,the
blower will switch over to the selected COOL speed.
• Ifthew terminal receives a call for heat during continuous
fan, the blower will de energize.
• Acallforfanisignoredwhileinlockout.
MAINTENANCE
Proper maintenance is most important to achieve the best
performance from a furnace. Follow these instructions for
years of safe, trouble free operation.
ELECTRICALSHOCK,FIREOREXPLOSION
HAzARD
Failuretofollowsafetywarningsexactlycould
resultinseriousinjuryorpropertydamage.
Improperservicingcouldresultindangerous
operation,serious injury,death or property
damage.
• Beforeservicing, disconnect all electrical
powertofurnace.
• Whenservicingcontrols,labelallwiresprior
todisconnecting.Reconnectwirescorrectly.
• Verifyproperoperationafterservicing.”
wARNING:
RISQUEDECHOCÉLECTRIQUE,D’INCENDIE
OUD’EXPLOSION
Le non-respect des avertissements de sécurité
pourraitentraîner
unfonctionnementdangereux
del’appareil,
desblessuresgraves,lamortou
desdommagesmatériels.
Unentreteinincorrectpourraitentraîner un
fonctionnementdangereuxdel’appareil,des
blessuresgraves,lamortoudesdommages
matériels
• Couper toute alimentation électrique au
générateurd’air chaudavantde prodéder
auxtravauxd’entretein.
• Aumomentdel’entretiendescommandes,
étiqueteztousleslsavantdelesdébrancher.
S’assurerdelesraccordercorrectement.
•S’assurer que l’appareil fonctionne
adéquatementaprésl’entretien.
AVERTISSEMENT:
• Thesemaintenanceinstructionsareprimarilyintended
to assist qualified technicians experienced in the proper
maintenance and operation of this appliance.
• Alwaysreinstallthedoorsonthefurnaceafterservicing
or cleaning/changing the filters. Do not operate the
furnace without all doors and covers in place.
• Verify the thermostat is properly installed and is not
being affected by drafts or heat from lamps or other
appliances.
• To achieve the best performance and minimize
equipment failure it is recommended that a yearly
maintenance checkup be performed. At a minimum,
this check should include the following items:
AirFilter- An air filter is not supplied with the furnace
as shipped from the factory. The installer must provide a
high velocity filter that is appropriately sized to the return
air duct opening or external filter rack.
wARNING:
Neveroperate the furnace without a lter in
place.Dustandlintcan builduponinternal
components, resulting in loss of efciency,
equipmentdamage,andpossiblere.
It is recommended that filter(s) be 1” or 2” thick and be
cleaned or replaced monthly. New or newly renovated
homes may require more frequent changing until the
construction dust has minimized.
Filters designed to remove smaller particles such as
pollen, may require additional maintenance. Filters for
side return and bottom return applications are available
from most local distributors.
BlowerCompartment- Dirt and lint can create excessive
loads on the motor resulting in higher than normal operating
temperatures and shortened service life. It is recommended
that the blower compartment be cleaned of dirt or lint
that may have accumulated in the compartment or on
the blower and motor as part of the annual inspection.
CleaningofBurners- If the burners must be cleaned,
follow steps 1 - 12. See Figure 20 (page 35) for component
location.
1. Shut off gas supply to the furnace at the meter or at a
manual valve in the supply piping.
2. Turn off all power to the furnace and set the thermostat
to its lowest setting.
3. Remove the burner door from the furnace.
4. Turn the gas control switch to the OFF position.
5. Disconnect the wires from the gas valve, igniter, flame
sensor, and flame rollout switch.