Installation Guide
15
Figure12.AlternateRemovalMethod
1
4
2
7
3
6
5
Alternate Bottom Panel Removal
If the bottom panel cannot be removed using the previous
instructions, the steps below are an alternate method for
removing the bottom panel. See Figure 12.
1. Remove the door (1) from the blower compartment .
2. Remove all screws securing the bottom panel (2) to the
front brace (3).
3. Remove two screws (4) securing the furnace cabinet
to the blower deck (5).
4. Remove all screws (6) securing the furnace cabinet to
the bottom panel (2).
5. Remove the screw (7) securing the bottom corner of
the furnace cabinet to the front brace (3).
6. Carefully spread the bottom corner of the furnace cabinet
outwards while sliding the bottom panel (2) out through
the front of the furnace.
7. Reassemble the furnace in reverse order.
BottomPanelRemoval
The steps listed below explain the proper method for
removing the bottom panel from the furnace. See Figure 11.
1. Remove the door (1) from the blower compartment.
2. Disconnect the blower motor wiring harness (2) from
the control board.
3. Remove two screws (3) securing the blower assembly
(4) to the furnace.
4. Carefully pull the blower assembly (4) out thru the front
of the furnace.
5. Remove all screws (5) securing bottom panel (6) to
bottom of furnace and front brace (7).
6. Lift up and slide bottom panel (6) out through front of
furnace.
7. Reinstall the blower assembly (4) in reverse order.
6
7
5
1
2
3
4
Figure11.BottomPanelRemoval
PressureSwitchTubing
Figure 10 displays the proper routing
of pressure switch tubing for *SA &
*SK furnaces. On both furnaces, the
tubing connects at one end of the
pressure switch and is routed directly
onto the static tap of the inducer
assembly.
Figure10.PressureSwitchTubingfor*SA&*SKFurnaces