01824A 03036A 01824B 03036B 03642B 030C 03648C 048C 060C 042D 048D 060D
NominalCapacity,MinBTUH 18,000 30,000 18,000 30,000 36,000
30,000
36,000
48,000 60,000 42,000 48,000 60,000
NominalCapacity,MaxBTUH 24,000 36,000 24,000 36,000 42,000 48,000
InstalledOriceSize(in.) .048 .061 .055 .067 .071 .061 .067 .077 .083 .071 .077 .083
NominalAirow,Min(CFM) 800 1,000 800 1,000 1,200
1,000
1,200
1,600 2,000 1,400 1,600 2,000
NominalAirow,Max(CFM) 800 1,000 800 1,200 1,400 1,600
W - Width (in.) 141/2 141/2 171/2 171/2 171/2 21 21 21 21 241/2 241/2 241/2
H-Height(in.) 203/4 203/4 203/4 203/4 263/4 263/4 263/4 301/4 301/4 301/4 301/4 301/4
HL-HeightofLiquidLine(in.) 171/2 171/2 171/2 171/2 231/2 231/2 231/2 27 27 27 27 27
HS-HeightofSuctionLine(in.) 151/2 151/2 151/2 151/2 211/2 211/2 211/2 25 25 25 25 25
Connection - Liquid Line 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Connection - Suction Line 3/4 3/4 3/4 3/4 7/8 3/4 7/8 7/8 7/8 7/8 7/8 7/8
HorizontalDrainKit 920265 920265 920265 920265 920266 920266 920266 920267 920267 920267 920267 920267
NOTES:
1. Individualrestrictorsareavailablebypartnumber-PN664***(where***representsthesize).Example:664103isarestrictor0.103indiameter.
2. RefertosalesspecicationsheetsforListed/Certiedcombinationsofequipmentandrequiredaccessories.
3. XinthemodeldescriptiondesignatesfactoryinstalledTXVforR-410arefrigerant.
4. RefertothecurrentAHRIDirectoryforcertiedratingsofsplitsystems.
5. Notrequiredfor“H”horizontalreadycoils.
Table 2A. C7BA Coil Specifications
Figure 5. Coil Dimensions
W
HS
HL
H
5/8
4
17 3/4
20 3/4
FRONT VIEW
TOP VIEW
01824A Horiz. 03036A Horiz. 01824B Horiz. 03036B Horiz.
NominalCapacity,MinBTUH 18,000 30,000 18,000 30,000
NominalCapacity,MaxBTUH 24,000 36,000 24,000 36,000
InstalledOriceSize(in.) .048 .061 .055 .067
NominalAirow,Min(CFM) 800 1,000 800 1,000
NominalAirow,Max(CFM) 800 1,000 800 1,200
W - Width (in.) 141/2 141/2 171/2 171/2
H-Height(in.) 263/4 263/4 263/4 263/4
HL-HeightofLiquidLine(in.) 231/2 231/2 231/2 231/2
HS-HeightofSuctionLine(in.) 211/2 211/2 211/2 211/2
Connection - Liquid Line 3/8 3/8 3/8 3/8
Connection - Suction Line 3/4 3/4 3/4 3/4
HorizontalDrainKit N/A N/A N/A N/A
NOTES:
1. Individualrestrictorsareavailablebypartnumber-PN664***(where***representsthesize).
Example:664103isarestrictor0.103indiameter.
2. RefertosalesspecicationsheetsforListed/Certiedcombinationsofequipmentandrequiredaccessories.
3. XinthemodeldescriptiondesignatesfactoryinstalledTXVforR-410arefrigerant.
4. RefertothecurrentAHRIDirectoryforcertiedratingsofsplitsystems.
5. Notrequiredfor“H”horizontalreadycoils.
Table 2B. C7BA Coil Specifications