Operating Guide
3
GENERAL INFORMATION
C7 Series indoor cased coils are designed for upflow,
downflow, or horizontal applications and are equipped with
braze type refrigerant connections for easy installation. If
aTXVisrequired,seeTable1todeterminetheproperkit
based on tonnage and refrigerant type of the unit.
• Checkthecoilsoricesizeandconrmthatit’ssuitable
for application with the intended outdoor unit. Depending
on application, additional installer supplied orifice or
TXVmayberequired.
• Optional cooling/heating equipment must be
properly sized and installed in accordance with the
furnace manufacturer’s specications and approved
recommendations.
• “HeatingOnly”furnaceaircirculatorsmayhavetobe
replacedwithmulti-speedheating/coolingblowersto
upgradetheairdelivery(CFM)whenanadd-oncoil
isinstalled.RefertoTables2Aor2B(page7)forcoil
specications,recommendedCFM,andallowancesfor
pressure drop across the coil and filters.
• Verifythattheairdeliveryofthefurnace/airhandleris
adequate to handle the static pressure drop of the coil,
filter, and duct work.
• Ifpreciseformingofrefrigerantlinesisrequired,acopper
tubing bender is recommended. Avoid sharp bends and
contact of the refrigerant lines with metal surfaces.
• Refrigerant lines should be wrapped with pressure
sensitive neoprene or other suitable material where
they pass against sharply edged sheet metal.
• Horizontalinstallationsrequireahorizontaldrainpan
kittobeinstalled.SeeTables2Aor2Bforavailable
part numbers.
• Close-off plates are available in some air lter kits.
RefertotheReplacementPartsListforavailablepart
numbers. Install the necessary close-off plates around
the refrigerant lines and drain line where required.
Reinstallallinnerandouterpanelsofthefurnace/air
handler that were previously removed when installing
the indoor coil.
COIL INSTALLATION
WARNING:
ELECTRICAL SHOCK, FIRE OR EXPLOSION
HAZARD
Failure to follow safety warnings exactly could
result in serious injury or property damage.
Improper servicing could result in dangerous
operation, serious injury, death or property
damage.
to the furnace and outdoor condensing unit.
to disconnecting. Reconnect wires correctly.
CAUTION:
The coil must be level to ensure proper
condensate drainage. An unlevel installation
may result in structural damage, premature
equipment failure, or possible personal injury.
NOTE TO INSTALLER: C7 Coils are not factory charged
with refrigerant. It will be necessary to evacuate the indoor
coiland lineset prior tocharging. Refer to theoutdoor
unit installation manual for detailed charging instructions.
Upflow Installations
1.Disconnectallelectricalpowertothefurnace.
2. Install the coil case on the furnace air discharge opening
and level it as needed to ensure proper condensate
drainage. If needed, make a plate to adapt the coil to
theairdischargeopening.SeeFigure5(page7)for
coil dimensions.
3.Makeandinstalltheplenumoverthecoil.Insulateas
required.
4. Seal the enclosure as required to minimize air leakage.
5.Connect the refrigerant lines as outlined in the
RefrigerantLineConnectionsection.
Horizontal Installations
C7 coils can be installed horizontally, but it is required
that the furnace and coil cabinets be securely mounted
together before setting in place. A horizontal drain pan
kitmustalsobeinstalledunderthecoil.RefertoTables
2Aor2B(page7)foravailablepartnumbers.
HorizontalLeftInstallations
1.Disconnectallelectricalpowertothefurnace.
2.Removethecoilaccessdoor.
3.Removetheplugandknockoutfromoneofthethreaded
holes in the horizontal drain pan.
SIZE of A.C. or H.P. (Tons)
R-22
Refrigerant
920662A 1.5or2
920663A 2.5
920664A 3
920665A 3.5
920666A 4
920667A 5
R-410A
Refrigerant
920668A 1.5or2
920669A 2.5
920670A 3
920671A 3.5
920672A 4
920673A 5