Use and Care Manual

9
Advanced Features:
-
Celsius or Fahrenheit
KELVIN can display the temperature in either Fahrenheit or
Celsius. The thermostat is factory set to Fahrenheit. To change it
to Celsius press and hold the
SHIFT
button, then press the
SET
TEMP
button. To go back to Fahrenheit repeat the same
process.
Press & hold
-
Temperature swing
Kevin has a variable temperature swing called Hysterisis. The
factory default setting is 2 degrees. This means that the
thermostat will continue to heat or cool to within one degree of the
set temperature. This enables your heating or cooling system to
work more efficiently minimizing its cycling time. This setting can
be adjusted from the factory setting of 2 by pressing and holding
the
SHIFT
button and pressing the
SET TIME
button. The
adjustable settings are 2, 4, and 6 degrees.
10
-Air Conditioning (
AC) Delay
This refers to a compressor delay for your AC system. The
compress delay protects your AC system from short cycling. If
your AC is turned off and then immediately turned back on again,
it could potential damage your AC system. To avoid this the
KELVIN waits 3 minutes before it turns the AC on again. This
option can be disabled, but be careful. Consult your owner’s
manual for your AC system, as this can cause potential damage.
To disable the AC delay press and hold the
SHIFT
button and
press “SET DAY”.
-Voice prompts
To turn off the voice prompts press the
VOICE
button. This will
cause the thermostat to go silent (except for the low battery
warning). To reactive voice prompts press the VOICE button
again
-Voice Commands recognition
To turn off voice commands press and hold the
SHIFT
button
while pressing the VOICE button. The READY icon on the
display screen will go out. To turn on voice recognition repeat the
same procure. The READY icon will be re-illuminated.