Instructions / Assembly
12
Advanced Settings
Gas/Electric Setting
- If your have an electric
system and the fan does
not operate after the
testing phase. You need to
change the Gas/Electric
jumper. To do this remove
the thermostat from the
wall and turn it over. On
the back you will see a
small opening. Put a
jumper on J13, to connect
the two pins. This will
enable electric mode.
Since this opening is very
small you will probably
need to use a pair of needle nose pliers or a tweezers.
13
Power Stealing
If you have problems with your
heating of cooling system not
turning off, you will need to remove
the jumper from J14. Again this
jumper is located in the little
window on the back of the
thermostat. Since this opening is
very small you will probably need to
use a pair of needle nose pliers or
a tweezers.
If your system contains a C wire,
then you can change J14 from
connecting the 2
nd
and 3
rd
pins to
the 1
st
and 2
nd
pins. This will
enable the thermostat to run without
any batteries. However batteries
should always be left in the unit
incase of a power failure. Please
remember to remove any jumpers
that might be installed across
terminals C and W or C and Y.
Failure to do so could result in
damage to the thermostat.