User's Manual

Table Of Contents
ELEC TRI CAL CON NEC TION
CA BLE SPEC I FI CA TIONS
32 Each cable is identified by a letter code which defines the type of cable required, e.g.
Cable code H is a 14-core cable. Table 1 provides specifications for each cable type.
Table 2 provides 14-core cable, colour code abbreviations.
33 The cables used to connect Kelvin Hughes equipment are to be to the following
specification. Failure to use the correct specification cables may result in impaired
equipment performance.
TABLE 1: Cable Specification
CABLE DESCRIPTION CODE CORE DIAMETER
A 2-core small multi-core 1344-718 0.5 mm 6.1 mm 6.9 mm
B 3-core small multi-core 1344-719 0.5 mm 6.4 mm 7.2 mm
C 4-core small multi-core 1344-720 0.5 mm 6.9 mm 7.7 mm
D 6-core small multi-core 1344-721 0.5 mm 7.9 mm 8.7 mm
E 12-core small multi-core 1344-722 0.5 mm 10 mm 11 mm
F Not used
G Not used
H 14-core composite 45-762-0116-001 Mixed 18 mm
I 2 x 1.5 mm Power (low) 45-762-0173-001 1.5 mm 8 mm
J Not used
K 2-core Power 5344-787 2.5 mm 12 mm
L 3-core Power 5344-788 2.5 mm 13 mm
N Not used
R Not used
KH1264
Chap ter 4