CHECKS AF TER UNIT RE PLACE MENT
38 Any maintenance, or rectification, involving the replacement of PCBs or Modules within
the Transceiver involves certain procedures to bring the Transceiver up to full working
order. The PCBs and Modules have been factory tested, and preset, and do not require any
adjustment. Therefore, no setting up procedures are required for the transceiver. However, if the
inverter in the Drive Control Unit is replaced the new inverter must be set up with the same
parameters as the replaced unit.
39 The following paragraphs and sub-paragraphs are procedures that the maintainer or
installer must follow to gain satisfactory performance of the equipment.
WARNING
DURING THESE PROCEDURES THE ANTENNA IS REQUIRED TO BE
ROTATING, CARE IS TO BE TAKEN IF CHECKS ARE TO BE MADE AT THE
TRANSCEIVER.
Trans ceiver
40 There are no setting up procedures required for the transceiver after a unit has been
replaced.
Drive Con trol Unit
41 The inverter in the Drive Control Unit must be programmed to provide the correct
frequency of rotation for the antenna. Refer to Chapter 5 for details of the commissioning
procedure for the inverter.
KH1264
Chap ter 6
Page 6.20 Is sue 2