User's Manual

SBS-900 Shore Based Radar Systems
Chapter 6: Local operation instructions
KH-1602-2 issue 1: Standard SBS900 Systems Operator & Maintenance Handbook
Page 67 of 240
6.6.5.7 SharpEye IP Tx A & B
Note: The Tx A or Tx B menu may not be present in single transceiver systems.
6.6.5.8 Rel Sector
The following menu displays the start and stop bearings of each of the four relative blanking sectors.
It also shows if the sectors are enabled or disabled.
R SEC START 1
Relative Sector 1
Displays the start bearing of mute
R SEC END 1 Displays the end bearing of mute
R SEC ENA 1
Shows if the Mute Sector is Enabled or Disabled
R SEC START 2
Relative Sector 2
Displays the start bearing of mute
R SEC END 2
Displays the end bearing of mute
R SEC ENA 2
Shows if the Mute Sector is Enabled or Disabled
R SEC START 3
Relative Sector 3
Displays the start bearing of mute
R SEC END 3
Displays the end bearing of mute
R SEC ENA 3 Shows if the Mute Sector is Enabled or Disabled
R SEC START 4
Relative Sector 4
Displays the start bearing of mute
R SEC END 4
Displays the end bearing of mute
R SEC ENA 4 Shows if the Mute Sector is Enabled or Disabled
EXIT
Exits the Rel Sector menu
6.6.5.9 Radar CNTRL (Control) Defaults
This menu displays the Radar Control Defaults settings.
Radar Source
Shows which t
ransceiver
is selected in
dual systems
Range mode Current instrumented range of 24nm or 48nm.
TX power Rb[ljDs_x ionjon jiq_l i` Kiq il bcab-
TX frequency
Shows which of the
SharpEye
TM
transmission frequencies is selected.
Mute Indicates if the Mute is switched ON or OFF.
SEA
Shows the configured value of the Sea filter (000
min.
to 255
max.
).
RAIN Shows the configured value of the Rain filter (000
min.
to 255
max.
).
Int
rejection
Shows if interference rejection is set to OFF or Lower.
Sweep
Shows if the sweep is set to Forward (default) or reverse.
RPM Shows the selected speed (revolutions per minute) of the antenna motor.
Exit
Exits the Radar control status menu.
FREQ/ HL
Skew
New sub menu + HL SKEW
Displays the Heading Line skew for each
SharpEye
frequency
that
is
enabled
.
Exit , Returns to the SharpEye IP menu.
FD Squint
To Be Confirmed
Blanking O/P New sub menu + Blanking Pre
Displays the value of the pre blanking
pulse.
Blanking Post
Displays the value of the post blanking
pulse.
Blanking
Threshold
TBC
Exit , Returns to the SharpEye IP menu.
Serial control
New sub menu
+
External COM 3
:
TBC
External COM 4: TBC
Exit , Returns to the SharpEye IP menu.
Video source Indicates which MISM PCA is the source the Video
AZ HL source
Indicates which MISM PCA is the source the ACP/ ARP
EXIT Exits the SharpEye IP Tx A or Tx B menu