User's Manual

SBS-900 Shore Based Radar Systems
Chapter 6: Local operation instructions
KH-1602-2 issue 1: Standard SBS900 Systems Operator & Maintenance Handbook
Page 66 of 240
6.6.5.4 Network
The Network menu shows the system settings for the network.
Note: In ASTERIX enabled systems, this menu may not be present.
Range limit 48nm is the factory default
Video
timing
Frame is the factory default
Video reports Continuous is the factory default
Local SAC SIC ID
To Be Confirmed.
Destination SAC SIC ID System area code and security identifier
IP ADDR Default IP address for the Radar Distribution Unit
Gateway
ADDR
Default gateway address for the Radar Distribution Unit
Network ADDR Default Netmask address for the Radar Distribution Unit
Multicast ADDR
Default multicast address for the Radar Distribution Unit
Time to Live To Be Confirmed.
MTU 1500 is the factory default
Fragment
IP is the factory default
Source port To Be Confirmed.
Dest port
To Be Confirmed.
Video Gain To Be Confirmed.
Video Offset To Be Confirmed.
Pre
-
Sync Time
To Be Confirmed.
Bihnlif Uc[} To Be Confirmed.
Exit
Exits the Network
menu
6.6.5.5 NTP time
Display of the NTP (Network Time Protocol) time settings.
Note: In ASTERIX enabled systems, this menu may not be present.
Time stamp Displays if NTP time is ON or OFF
NTP IP ADDR
Shows the default IP
address (192.168.022.071)
NTP port Shows the default port (00123)
6.6.5.6 OP1, 2 & 3 Radar O/P
This menu displays the RDU analogue levels for outputs 1, 2 and 3.
HL O/P widths Displays the heading line output pulse width
AZ
O/P width
Displays the azimuth output pulse width
AZ/HL STAB
Displays if the azimuth is stabilised or unstabilised.
This is set to UNSTAB for all SBS-900 systems
AZ/HL type
Displays if the Heading line is Quadrature or Pulsed.
This is set to Pulse for all SBS-900 systems
AZ/HL ratio
Displays the Azimuth / Heading Line ration.
This is set to 4096:1 for all SBS-900 systems
AZ/HL DIRECTN
Set to Normal for all SBS
-
900 systems
AZ/HL O/P
Displays a value between 0 and 63 that is used to set the azimuth and heading line
output voltage.
Note
Video gain Displays a value between 0 and 63 that is used to set the video output gain.
Note
Video offset
Displays a value between 0 and 63 that is used to set the video output offset with
respect to ground/ 0V.
Note
PRESYNC time Displays the pre-sync (Sync Delay) time used for range alignment.
Sync output
Displays a value between 0 and 63 that is used to set the Sync output.
Note
Blanking O/P
Displays a value between 0 and 63 that is used to set the blanking output
amplitude
Note
EXIT
Exits the OP1, 2 or 3 Radar O/P menu
Note: This is NOT an indication of the actual voltage output level.