User's Manual

SBS-900 Shore Based Radar Systems
Chapter 6: Local operation instructions
KH-1602-2 issue 1: Standard SBS900 Systems Operator & Maintenance Handbook
Page 57 of 240
6.6.4.2 Radar Control Status
By scrolling through the Radar Control Status menus, the following system configurations and settings
can be viewed but not adjusted.
A full description of each function is shown in the Control menu section 6.6.3 pages 51 onwards.
Radar Source Transceiver A or B selection in dual systems
Range mode Current instrumented range of 24nm or 48nm.
TX power Rb[ljDs_x ionjon jiq_l i` Kiq il bcab-
TX frequency Shows which of the 7 SharpEye
TM
transmission frequencies is selected.
Mute Indicates if the Mute is switched ON or OFF.
SEA Shows the configured value of the Sea filter (000
min.
to 255
max.
).
RAIN Shows the configured value of the Rain filter (000
min.
to 255
max.
).
Int rejection Shows if interference rejection is set to OFF or Lower.
Sweep Shows if the sweep is set to Forward (default) or reverse.
RPM Shows the selected speed (revolutions per minute) of the antenna motor.
Rel sector 1
Rel sector 1 to 4 will show Enabled or Disabled for each blanking sector.
When Enabled, the start/ stop bearings of the selected sector is also shown.
Rel sector 2
Rel sector 3
Rel sector 4
Exit Exits the Radar control status menu.