User's Manual
SBS
-
900 Shore
Ba
Ba
sed
Radar Systems
Chapter
6
:
Local operation instructions
KH
KH
-
1602 2
issue 1
:
Standard SBS900 Systems Operator & Maintenance Handbook
Page
40
40
of
240
6.2.6
Alarms
When
the system is in
Local
control
Note
1
and
an alarm
condition exists, the lower right button will flash
red and an audible alarm will be generated.
View alarm condition:
To view the alarm message/ condition,
select the
S
tatus
menu
and the alarm condition(s) will be
displayed in the lower section of the LCD display.
Where present, the
,
symbol against
the lower right
button
indicates that additional alarm conditions exist. Pressing the
,
button scrolls through any additional alarm
messages.
Silence the audible alarm:
To silence the alarm, select the
Status
menu and then press the lower right hand (red/ flashing) button.
The
audible
alarm will be silenced but the message will continue to
display until the condition is cleared.
Example
Note
2
:
In the example shown below, an X
-
band transceiver
is in
Local
control with a
displayed indicating that the AC mains input B has failed
, is switched OFF or there is a
fault with the power supply.
The
and
arrows allow navigation away from the alarm
messages to other functions available within the Status menu (see
section
6.6.4
pages 56
56
onwards).
Additional alarms conditions are present as indicated by the
,
symbol.
The
%
symbol return
s the display to the main menu.
Example of system status
with active alarms
When an
alarm has been acknowledged and more than one alarm condition exists, the display
automatically scrolls through the list of alarms.
Note
1
:
When the
Radar Distribution Unit
is set to
Remote
, alarm messages are still generated and displayed but the audible
alarm and flashing
warning
LED is disabled.
Note
2
:
The alarm shown is an
example
and
may not be a valid alarm for the SBS
900
system
.